ML19321A178

From kanterella
Jump to navigation Jump to search
Forwards LER 80-098/03L-0
Date released: 12/01/2019 Download: ML19321A178


LER 80-098/03L-0:on 800624,during heat-up,tee Fitting on Pressurizer Pressure Sensing Line for Instrument 1-PI-68-323 Failed,Allowing Primary Coolant to Leak Into Containment. Caused by Improper Installation of Ferrule Ring on Tee
ML19321A183
Person / Time
Site: Sequoyah 
Issue date: 07/18/1980
From: Emrath R
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19321A183 (1)
Forwards LER 80-098/03L-0
ML19321A177
Person / Time
Site: Sequoyah 
Issue date: 07/18/1980
From: Calhoun J
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19321A177 (1)