ML19320D596

From kanterella
Jump to navigation Jump to search
Certificate of Compliance 5998,Revision 2,for Model GE-400
ML19320D596
Person / Time
Site: 07105998
Issue date: 07/09/1980
From: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To:
Shared Package
ML19320D595 List:
References
NUDOCS 8007210587
Download: ML19320D596 (2)


Text

k._ _

p)

Form NRC.618 U.S. NUCLEAR. REGULATORY COMMISSION I'

CERTIFICATE OF ' COMPLIANCE 3n C R 71 For Radioactive Materials Packages

~

1.(a) Certificate Number 1.ib) Revision No.

1.(c) Package identification No.

1.(d) Pages No. 1.(e) Total No. Pages R00R 7

IKA/RooR/R( )

1 9

2. PREAM8LE 2.(a)

This certificate is issued to satisfy Sections 173.393a.173.394,173.395, and 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170189 and 14 CFR 103) and Sections 146--19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.

2.tb)

The packaging and contents described in item 5 below, rneets the safety standards set forth in subpart C of Title 10. Code of Federal Regulations. Part 71," Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions" 2.fc)

This certificate does not te eve the consignor from compliance with any reouirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.

3. This certificate is issued on the basis of a safety analysis report of the package design or applicatior>-

3.la)

Prepared by (Name and address):

3.(b)

Title and identification of report orspolicati n:

9 General Electric Company General Electric -Company application P.O.. Box 460 dated February 21, 1980.

Pleasanton, CA 94556 3.lc)

Docket No.

4 CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable, and the conditions specified in item 5 below.

5. Description of Packaging and Authorized Contents. Model Number. Fissile Class. Other Conditions, and

References:

)

(a) Packaging (1) Model nom GE-400 (2) Description.

Steel encased lead shielded shipping cask.

A double-walled steel cylinder protective jacket encloses the cask during transport.

It is bolted to a steel pellet.

The cask is closed by a lead-filled flanged plug fitted with a silicone rubber gasket and bolted closure. The physical description is as follows:

Cask height (in) 24.1 Cask diameter (in)

~20.0 Cavity height (jn) 3.0 Cavity diameter (in) 2.4 Lead shielding (in) 8.3 Protective jacket height (in) 29.7 l

Protecti0e jacket width (in) 32.0 Packaging weight (1bs) 3,800 8007210 M

-.c.

..,--,. 4..

.. ~

Page 2 - Certificate No. 5998 - Revision No. 2 - Docket No. 71-5998 5.

(a) Packaging (continued)

(3) Drawings The packaging is constructed in accordance with the following General Electric Company Drawing Nos.:

856B880, Re/. 7 106D3980, Rev. 2 277E411, Rev. 2 10603983, Rev. 2 178B9960, Rev. 0 (b) Contents (1) Type and form of material Byproduct material meeting special form requirements of 10 CFR 671.4(o).

(2) Maximum quantity of material per package Radioactive decay heat not to exceed 400 watts.

6.

Shoring shall be provided to minimize movement of contents during accident conditions of transport.

7.

Package contents shall be delivered to a carrier dry.

8.

Prior to each shipment the silicone rubber lid gasket shall be inspected.

This gasket shall be replaced if inspection shows any defects or every twelve (12) months, whichever occurs Tirst.

Cavity drain line shall be sealed with appropriate sealant applied to threads of pipe plug.

9.

The package authorized by this certificate is hereby af.p :ved for use under the general license provisions of 10 CFR 671.12(b).

10.. Expiration date:

July 31, 1985.

REFERENCE General Electric Company application dated February 21, 1980.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION 8

Charles. MacDonald, t,hief Transportation Certification Branch Division of Fuel Cycle and Material Safety Date:

JUL 0 91980

.