7 o
Appendix A O
NOTICE OF VIOLATI;01 Kerr-McGee Nuclear Docket No. 70-1193 Corporation Based on the inspection conducted on April 7 and 8, 1980, it appears that certain of your activities were in noncompliance with NRC requirements, as noted below. This item is a deficiency.
Item 9.0(c) of the licensee's application dated November 29, 1978, which was incorporated as Amendment No. 3 to license No. SNM-1174, states, "No empty or partly filled drums (or other shipping containers) will be placed in room 121."
Contrary to this requirement, on April 8, 1980, the inspector, accompanied by a licensee representative, observed empty drums in room 121.
i 8007170805