Text

_.

07/15/80

,_1 c.

UNITED STATES OF AriERICA NUCLEAR REGULATORY COMt11SSI0ti BEFORE THE AT0t11C SAFETY AND LICENSING BOARD In the Matter of

)

)

GENERAL ELECTRIC C0f1PANY

)

Docket No. 70-1308

)

(Renewal of Sfitl-1265)

(GE florris Operation Spent

)

Fuel Storage Facility)

)

NRC STAFF INTERR0GATORIES T0, AND REQUEST FOR THE PRODUCTION OF DOCUMENTS FR0tl, INTERVENOR R0REN, ET AL.

The Nuclear Regulatory Commission (NRC) Staff hereby requests that Intervenor Rorem, et al., pursuant to 10 CFR 6 2.740b and in accordance with the Atomic Safety _ and Licensing Board's Order Extending Schedule for Discovery of June 23, 1980, answer separately and fully, in writing under oath or affirma-tion, the following interrogatories.

I For each response to the interrogatories set forth below, identify the per-son or persons who prepared or substantially contributed to the preparation 3

of the response.

The NRC Staff further requests that Intervenor Rorem, et al., pursuant to 10 CFR % 2.741, provide copies of, or make available for Staff inspection and copying, the documents designated by Intervenor in response to certain of the accompanying interrogatories.

t I

/

l 800 717 0 Mb C.

t

I.

General InterrogatoriesM G-1 State whether or not you intend to call any person or persons as witnesses in this proceeding in support of (a) Contention 1(b)

(b) Contention 2 (c) Contention 6 and provide the names, addresses, educational backgrounds and professional qualifications of those persons you intend to call.

G-2 Indicate which of those persons identified in response to Interroga-tory G'1 will appear voluntarily and which persons you intend to subpoen x.

G-3 Provide summaries of the views, positions, or proposed testimony on (a) Contention 1(b)

(b) Contention 2 (c) Contention 6 of all persons named in response to Interrogatory G-1 that you intend to present during this proceeding.

1/ -

Interrogatories in this section should be answered with respect to each contention. The contentions referred to are those contentions raised by Intervenor as modified, renumbered and admitted by the Licensing Board in its Order Ruling on Contentions of the Parties issued on June 4,1980.

G-4 Identify by author, title, date of publication and publisher, all books, documen_ts and papers that you intend to employ or rely upon in presenting your direct case on (a) Contention 1(b)

(b) Contention 2 (c) Contention 6 i

and provide copies of, or make available for Staff inspection and copying, those iteas.

4 G-5 If the representations made in (e) Contention 1(b)

(b) Contention 2 (c) Contention 6 are based in whole or in part on any documents prepared by the Licensee or NRC Staff which you contend are deficient, identify the docunents and specify the particular portions thereof you

)

regard as deficient and explain why they are deficient.

i G-6 Identify by author, title, date of publication and publisher, all

. books, documents-or papers that you intend to employ or rely upon in conducting your cross-examination of prospective NRC Staff witnesses testifying in connection with (a) Contention 1(b)

(b) Contention 2 (c) Contention 6 y-e 3

.---+g-%

o-.

e

(d) Board Question 1 as set forth in the Order Ruling on Contentions of Parties, dated June 4, 1980.

II.

Interrogatories Related to Specific Contentions /

Contention 1(b)

Cl-1 Define " risks" as that term is used in Contention 1(b) and speci-fically as the term is used with regard to parts (1) through (ix) ofContention1(b).

Cl-2 As to Contention 1(b)(1):

(a) describe the tornado impelled missile referred to and state the basis for the assertion that such a missile could be generated by a tornado and could impact the Morris Spent Fuel Storage Facility; (b) describe the tornado missile accident referred to and state the basis for the assertion that such an accident could be caJsed by a tornado missile at the Morris Spent Fuel Storage Facility; 2/

The contentions referred to are those contentions raised by Inter-venor as modified, renumbered and admitted by the Licensing Board in its Order Ruling on Contentions of the Parties issced on June 4,1980.

-r w

- m wr

--w-

(c) describe the tornado missile accident consequences referred to and state the basis for your assertion that such consequences could occur;-

(d) state the basis for your assertion that radioactive releases fron a tornado missile accident could exceed 10 CFR Part 20 limits; a

(e) indicate the CSAR description of the risks and conse-j quences of tornado missile accidents that you, would consider to be adequate and provide the basis for your r

position in this regard.

l Cl-3 As to Contention.1(b)(ii):

(a) specifically describe the loss of coolant accident referred to, describe the mechanism causing such loss of coolant accident, and state the basis for your assertion that such loss of coolant accident could occur; (b) identify the " building structure" and describe the

{

"rif t" in the building structure referred to, describe

.the mechanism or accident causing such a " rift," and state the basis for your assertion that such a -rift could occur;

6-(c) state the basis for your assertion that the loss of coolant accident could occur ir. conjunction with an accident causing a rift in the building structure; (d) describe the consequences (referred to in Contention 1(b)(ii)) of a loss of coolant accident alone and the basis for your assertica that such consequences could occur; i

(e) describe the consequences (referred to in Contention 1(b)(ii)) of a loss of coolant accident in conjunction with an accident causing d rift in the building struc-ture and state the basis for your assertion that such consequences could occur; (f) state the basis for your assertion that radioactive releases from a loss of coolant accident alone or a loss of coolant accident in conjunction with an accident causing a rift in the building structure could exceed 10 CFR Part 20 limits; (g) indicate the 'CSAR description of the risks and conse-quences 'of a loss of coolant accident and of a loss of coolant accident in conjunction with an accident causing a rift in the building structure that you would consider n

-e gme

1 1

to be adequate and provide the basis for your position in this regard.

Cl-4 As to Contention 1(b)(iii);

l (a) describe specifically and in detail the " earthquake-related accidents" referred to and state the basis for your assertion that each of those accidents could result from the earthquakes the facility is required to resist.

under the existing facility license; (b) describe the consequences (referred to in Contention 1(b)(iii)) of the identified earthquake-related acci-dents and state the basis for your assertion that such consequences could occur; (c) state the basis for your assertion that radioactive releases from earthquake-related accidents could exceed 10 CFR Part 20 limits; (d) indicate the CSAR description of-the risks and conse-1 quences of earthquake-related accidents that yjy> would consider to be adequate and provide the basis for your position in this regard.

. O Cl-5 As to Contention 1(b)(iv):

(a) describe specifically the " sabotage-related accidents not analyzed in f1ED'i-20682" which ycu assert should be considered and state the basis for your assertion that such accidents could occur and should be evaluated; a

(b) describe the consequences (referred to in Conten-tion 1(b)(iv)) of the identified sabotage-related acci-dents and state the basis for your assertion that such consequences could occur; (c) state the basis for your a:sertion that radioactive releases from sabotage-related accidents could exceed 10 CFR Part 20 limits; (d) indicate the CSAR description of the risks and conse-quences of sabotage-related accidents that you woald consider to be adequate and, vide the basis for your position in this regard.

Cl-6 As to Contention 1(b)(v):

(a) describe specifically the " fire"-related consequences referred to and state the basis for your assertion that such occurrences could take place;

o 9-(b) describe the consequences (referred to in Conten-tion.1(b)(v)) of the identified fire-related occurrences and state the basis for jour assertion that such conse-quences could occur;

)

e

]

(c) state the basis for your assertion that radioactive releases froa fire-related occurrences could exceed 10 CFR Part 20 limits; i

t i

(d) indicate the CSAR description of the risks and conse-i quences of fire that yjg[ would consider to be adequate 1

l and provide the basis for your position in this regard.

i Cl-7 As to Contention 1(b)(vi):

i (a) define what is meant by " flooding" as that term is used in the contention, describe the mechanisms (both natural and mannade) which you assert could cause " flooding,"

and state the basis for your assertion that such mech-anisms could cause " flooding;"

(b) describe the consequences (referred to in Conten-tion 1(b)(vi)) of flooding, indicate the manner in which

. flooding could cause releases of radioactivity and state t

s a

n

the basis for your assertion that flooding could result in the described consequences and/or releases of radio-activi ty; (c) state the basis for your assertion that radioactive releases fron flooding could exceed 10 CFR Part 20 limits; i

(d) indicate the CSAR description of the risks and conse-quences of flooding that yjx[ would consider to be ade-quate and provide the basis for your position in this regard.

Cl-8 As to Contention 1(b)(vii):

(a) state the basis for your assertion that " acts of war" can be considered in this license renewal proceeding, c' ting any provisions of statutes or regulations which, to your knowledge, support your assertion;

-(b) define what.is meant by " acts of war" as that phrase is used in the contention and describe the " acts of war" to which you refer in the contention; e

m e-4 7

e 4

(c) describe the consequences (referred to in Conten-tion.1(b)(vii)) of the " acts of war," state the basis for your assertion that such consequences could occur, t

and state the basis for your assertion that consequences fraa " acts of war" could exceed 10 CFR Part 20 limits; (d) indicate the CSAR description of the risks and conse-4 quences of " acts of war" that yjn[ would consider to be adequate and provide the basis for your position in this regard.

Cl-9 As to Contention 1(b)(viii):

(a) describe specifically the " human error"-related occur-rences referrea to in the contention;

.(b) describe any instances (including date and citations to any reports on the matter) of the occurrence of human error resulting in accidents or the release of radio-activity at the GE Morris facility of which you are aware; (c) describe the consequences (referred to in Contention 1(b)(viii)) of human error-related occurrences and state the basis for your assertion that such consequences could result; 1

- 9.;

, ~,,

--.%~~

O e.

(d) state the basis for your assertion that radioactive releases from human error could exceed 10 CFR Part 20 limits; (e) indicate the CSAR description of the risks and conse-quences of human errors that jggt would consider to be I

adequate and provide the basis for your position in this regard.

C1-10 As to Contention 1(b)(ix):

(a) define what is meant by " massive electrical power fail-ure" as that phrase is used in the conteqtion, describe the mechanisms (both natural and manmade) which you assert could cause " massive electrical power failure,"

and state the basis for your assertion that such mech-anisms could cause the powet failure; (b) describe the consequences (referred to in Conten-tion 1(b)(ix)) of massive electrical power failure, indicate the manner in which such power failure could cause releases of radioactivity, and state the basis for your assertion that massive electrical power failure could result'in the described consequences and/or releases of radioactivity;

(c) state the basis for your assertion that radioactive releases from massive electrical power failure could exceed 10 CFR Part 20 limits; (d) indicate the CSAR description of the risks and conse-quences of massive electrical power failure that you would consider to be adequate and provide the basis for your position in this regard.

Contention 2 C 2-1 State specifically the reasons why the GE Morris Physical Security Plan does not meet the requirements of 10 CFR Part 73.

Include in your response an identification of the specific sections of 10 CFR Part 73 which you believe are not met and provide the basis for your assertions that those sections are not met.

C2-2 Describe in detail the " advances in the technology of explosives" referred to in Contention 2 and state the basis for your assertion that such " advances in the technology of explosives... could make sabotage a more probable event" at the GE Morris facility.

C2-3 Indicate the CSAR assessment of credible risks of sabotage-related events accounting for advances in the technology of explosives that you,would consider to be adequate and provide the basis for your position in this regard.

14 -

Contention 6 C6-1 As to Contention 6(a):

(a) describe the " area," in terns of distance fro 1 the Morris facility, for which you believe comprehensive evacuation planning is necessary and provide the detailed basis for your response; (b) what is the basis for your assertion that Joliet and Kankakee might need to be evacuated?

C6-2 As to Contention 6(b):

(a) what is meant by "large numbers of people" as that phrase is used in Contention 6(b)?

(b) describe the accident or event that you assert would result in the exposure and/or contamination of "large numbers of people" and provide the basis for your asser-tion that such an accident could occur at the Morris facili ty.

C 6-3.

As to Contention 6(c), you state that the Applicant should be l

responsible.for informing area residents "that the possibility of such an accident does exist." Specifically describe the accident

0 or accidents referred to (the response sought is a description of specific accident scenarios rather than a general response such as "any accident requiring evacuation") and provide the basis for your assertion that such accidents could occur.

C 6-4 As to Contention 6(d), describe in detail the specific inade-quacies in the Applicant's emergency planning which exist with regard to " formation of evacuation plans," " equipping hospitals,"

" training personnel," and "for maintenance of any equipment needed."

In your view, what more should be done by the Applicant with regard to these natters and why?

Respectfully subnitted,

/k Mc sep R. Gray !,

ou el for f1RC Staff

. Dated at Bethesda, flaryland this 15th day of July,1980 l