a Q)
Firm NRC418 U.S. NUCLEAR REGULATORY CoMMISSloN o2 3)
CERTIFICATE OF COMPLI ANCE 3g g p 73 For Radioactive Materials Pachges 1.bl Certificate Number 1.(b) Revision No.
1.(c) Package Identification No.
'(d) Page No. 1.(e) Total No. Pages 4888 4
USA /4888/B( )
. 1 3
- 2. PREAMBLE 2.(a)
This certificate is issued to satisfy Sections 173.393a.173.394,173.395. and 173.396 of the oepartrnent of Transportation Hazardous Materials Regulations (49 CFR 170189 and 14 CFR 103) and Sections 146-19-10a and 146--19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149). as amende$.
2.(b)
The packaging and contents described in item S below, meets the safety standards set forth in Subc.st C of Title 10. Code of Federal Regulations, Part 71, "Pacuaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions.**
2.(c)
This cartificate does not relieve the consignor from comoliance with any requirement of the regulations of the U.S. Department of Transportation or other apolicaele regulatory agencies. including the government of any country through or into which the package will be transported.
- 3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.la)
P ecared by (Name and address):
1(b) Titig and identification of report or app'ication:
4 Teledyne energy Systems Martin Company application dated 110 West Timonium Road August 13, 1965, as supplemented.
Timonium, MD 21093 71-4888 3.lc)
Docket No.
4 CCNDITioNS This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as acplicable, and the conditions specified in item 5 below.
S. Description of Packaging and Authorized Contents. Model Numcer, Fissile C: ass. Other Conditions, and
References:
(a) Packaging (1) Mode'l Nos.:
Sentinel-25A, LCG-25A; Sentinel-258, LCG-25B; Sentinel-25C, LCG-25C; Sentinel-25C3,-250,-25E, and-25F (2) Description The packages are thermoelectric generators.
The major components include the main housing, tungsten shield, housing flange, and electrical connectors.
The app.oximate dimensions and weights for the various Model Nos. are as fo? lows:
Model No.
Dimensions (inches)
Weicht (lbs.)
Sentinel-25A, LCG-25A 25 OD x 25 3000 1
Sentinel-25E, LCG-25B
.25 00 x 25 3300 Sentinel-25C, LCG-25C 24 OD x 32 2000 Sentinel-25C3 24 OD x 32 1300 Sentinel-250 25 00 x 27 3300 Sentinel-25E 25 OD x 34 4200 Sentinel-25F 24 OD x 32 1400 (3) Drawings The packagings are constructed in accordance with the following Drawing Nos:
i 8007160 387
Page 2 - Certificate No. 4888 - Revision No. 4 - Docket No. 71-4888 5.
(a) Packaging (continued)
(3) Drawing Nos.
Model No.
Drawino Nos.
All Models Isotopes, Inc. Drawing Nos.:
001-20000 001-20001 001-20002 001-20003 Sentinel-25A, LCG-25A' Martin Company Drawing Nos.:
N0013100 N0013108 N0013113 PN1000003 Sentinel-25B, LCG-253 Martin Company Drawing Nos.:
N0013200 N0013208 Sentinel-25C, LCG-25C Isotopes, Inc. Drawing Nos.:
Sentinel-25C3 001-C10000 001-70012 001-40019 Sentinel-25D Isotopes, Inc. Drawing Nos.:
Sentinel-25E 001E10000 Sentinel-25F 001010000 001F10000 001-70033 001-70024 001-40006 001-40015 001-40017 (5) Conte-ts (1) Tyr2 and form of material (i)
Strontium 90 titanate doubly encapsulated in a Hastelloy or Uniloy fuel capsule which meet the requirements of special form as Gefined is 10 CFR $71.4(o); or (ii) Model No. Sentinel-25F may have, strontium fluoride doubly encapsulated in a Hastelloy or Uniloy fuel capsule, with a Hastelloy C-276 liner which meets the requirements of special form as defined in 10 CFR 571.4(o).
(2) The maximum quantity of material per package 125,000 curies
O Page 3 - Certificate No. 4888 - Revision No. 4 - Dec et No. 71-4888 6.
Eye-bolt shall be remcVed or covered during transportation to prevent their use as tie-down devices of packages.
7.
The packages authorized by this certificate are hereby approved for use under the general license provisions of 10 CFR 571.12(b).
8.
Expiration date:
July 31, 1985.
l REFERENCES Zsotopes, Inc. applications dated September 15 and 16, 1969; and March 3 and April 20, 1970.
Model No. Sentinel-25A, and LCG-25A Martin Company application dated October 28, 1965; with supplements dated:
January 14, April 1, and July 21, 1966.
Model No. Sentinel-253, and LCG-25B Martin Company application dated March 21, 1967.
Model No. Sentinel-25C, and LCG-25C Martin Company application dated August 16, 1967' with supplements dated:
September 1, and September 15, 1967.
Model No. Sentinel-25C3 Isotopes, Inc. application dated September 10, 1969; with supplement dated:
October 30, 1969.
Model No. Sentinel-250, and 25E Zsotopes, Inc. application dated December 16, 1968: with supplements dated December 26, 1958 and January 10, 1969.
Mooel No. Sentinel-25F Isotopes, Inc. application dated March 27, 1970; with supplement TES-MIH-1403 dated:
January 25, 1978.
FOR THE U.S. NUCLEAR REGULATORY COMMISSION l
~
Charles E. MacDonald, Chief p'
Transportation Certification 2 anch L
Division of Fuel Cycle and Material Safety JtJL 0 71980 De