006FQs UNITED STATES
/p* "8%q'o,$
NUCLEAR REGULATORY COMMISSION REGloN IV
- T )M I 3 I 3
611 RYAN Pt.AZA DRIVE,SulTE 1000
-f ARLINGTON, TEXAS 76012
",.y, s mA.
19 MAY 1980
%, v.....e Docket No. 99900521/80-02 Bechtel Power Corporation Los Angeles Power Division Attn: Mr. I. R. Caraco Vice President and General Manager P. O. Box 60680 Terminal Annex Los Angeles, California Gentlemen:
This refers to the QA Program inspection conducted by R. H. Brickley of this office on April 28 - May 1, 1980 of your facility at Norwalk, California and to the discussions of our findings with Mr. J. V. Morowski and members of your staff at the conclusion of the inspection.
Areas examined during the QA Program inspection and our findings are discussed in the enclosed report. Within these areas, the inspection consisted of an examination of procedures and representative records, interviews with personnel, and observations by the inspector.
Within the scope of this inspection, we found no instance where you failed to meet NRC requirements.
In accordance with Section 2.790 of the Commission's " Rules of Practice,"
Part 2, Title 10, Code of Federal Regulations, a copy of this letter together with the enclosed inspection report will be placed in the Commission's Public Document Room.
If this report contains any information.that you believe to be proprietary, it is necessary that you t;ake a written application within thirty (30) days to this' office to withhold such information from public disclosure.
j Any such application must include a full statement of the reasons on the basis of which it is claimed that the information is proprietary, and should be prepared so that proprietary information identified in the application is l
i contained in a separate part of the document.
If we do not hear from you in this regard within the specified period, the report will be placed in the Public Document Room.
8007160Noh-
._..I
Bechtel. Power Corporation 2
Should you have any questions concerning this inspection,.we will be pleased to discuss them with you.
Sincerely, t
/
%Q U dis ocapovs, lef Vendor Inspection Branc.1
Enclosure:
Inspection Report No. 99900521/80-02 l
,I t