ML19320C078

From kanterella
Jump to navigation Jump to search
Advises That IE Info Notice 80-27, Degradation of Reactor Coolant Pump Studs, Was Sent to Listed Utils on 800611
ML19320C078
Person / Time
Issue date: 06/12/1980
From: Pappas H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To: Wright G
ILLINOIS, STATE OF
Shared Package
ML111960099 List:
References
NUDOCS 8007150770
Download: ML19320C078 (2)


Text

f,cn

'o UNITED STATES

[ ),,

},

NUCLEAR REGULATORY COMMISSION 3C

,a REGION 111 Y

799 ROOSEVELT ROAD 6

GLEN ELLYN, ILLINOIS 60137 o

AN I ? ggg State of Illinois Department of Public Health ATTN:

Mr. Gary N. Wright, Chief Division of Nuclear Safety 535 West Jefferson Street Springfield, IL 62761 Gentlemen:

The enclosed IE Information Notice No. 80-27 titled " Degradation of Reactor Coolant Pump Studs" was sent to the following licensees on June 11, 1980.

American Electric Power Corporation Indiana and Michigan Power Company D. C. Cook 1, 2 (50-315, 50-316)

Commonwealth Edison Company Braidwood 1, 2 (50-456, 50-457)

Byron 1, 2 (50-454, 50-455)

Zion 1, 2 (50-295, 50-304)

Consumers Power Company Midland 1, 2 (50-329, 50-330)

Palisades (50-255)

Northern States Power Company Prairie Island 1, 2 (50-282, 50-306)

Public Service of Indiana Marble Hill 1, 2 (50-546, 50-547)

Toledo Edison Company Davis-Besse (50-346)

Union Electric Company Callaway 1, 2 (50-483, 50-486)

Wisconsin Electric Power Company Point Beach 1, 2 (50-266, 50-301) 8007150770

-JUN 121980

[*-

-- State of Illinois F Wisconsin Public Service Corporation Kewaunee (50-305)

Sincerely, hrN ff Helen Pappas, Chief Administrative Branch

Enclosure:

IE-Information Notice No. 80-27 cc w/ encl:

Mr. D. W. Kane, Sargent & Lundy Central Files Reproduction Unit NRC 20b Loca1-PDR NSIC TIC f

4 W

l e

n

.m r