ML19320B883
| ML19320B883 | |
| Person / Time | |
|---|---|
| Site: | Waterford |
| Issue date: | 06/17/1980 |
| From: | Aswell D LOUISIANA POWER & LIGHT CO. |
| To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE) |
| References | |
| IEB-80-09, IEB-80-9, LPL-14321, NUDOCS 8007150417 | |
| Download: ML19320B883 (1) | |
Text
.a l
W 0;
P O W E R & L 1 G H T! p.42 DELARONDE STREFT 1
- o. Box 6008 NEW C'1 LEANS. LOUISIANA 70174. (504) 366-2345 UTruTIES SYSTEM o L ASWELL Vce PresWeet-Power Produccan June 17, 1980 LPL 14321 Q-3-A20.03.14 E
U. S. Nuclear Regulatory Comission Director of Reactor Construction Inspection, 0.I.E Washington, D. C.
20555
SUBJECT:
Waterford 3 SES Docket No. 50-382 IE Bulletin No. 80-09 Hydracotor Actuator Deficiencies Interin Reply
~
~
Dear Sir:
We have detemined that aH-90 and NH-90 series Hydramotor Actuators manufactured by ITT General Controls will be used in s:sfety-related systems.
The problems described in the subject bulletin are being investigated by the affected equipment s,uppliers. A test report fron ITT General Controls is required to complete their investigation. This r Oort is scheduled for completion during the week of June 23, 1980.
We expect to have all the equipment suppliers' reports and to have completed our engineering review by August 29, 1930 at which ti=c we will submit our final report.
If you have any questions, please advise.
Yours,very truly, D. L. Aswell DLA/WMF/dde-cc:
Mr. Karl V. Seyfrit, Director Region IV U. S. Nuclear Regulatory Comission Of fice of Inspection and Enforcement 611 Ryan Plaza Drive Arlington, Texas 76012 8007150 W Q
.