Advises That Dates of Responses to 790927 Generic Ltr Were 791025 for Peach Bottom 2 & 3 & 791115 for Hatch 1 & 2.Rept on Valve Operability Program Required Only for Plants Desiring to Justify Unlimited Purging
ML19320B712
Person / Time
Site: Peach Bottom, Hatch  
Issue date: 06/05/1980
From: Verrelli D
Office of Nuclear Reactor Regulation
To: Zudans J
Office of Nuclear Reactor Regulation
References
NUDOCS 8007140641
Download: ML19320B712 (1)


Text

-

'8%

g{

.c UNITED STATES

(.

,, q NUCLEAR REGULATORY COMMISSION r, pl g (/j/

3 n,

[h") ]

WASHINGTON, D. C. 20555 g,

t+

v4 977 3#

June 5, 1980 3 L Ce MEMORANDUM FOR: John Zudans, EQB, Division of Engineering FROM:

D. M. Verrelli, Project Manager, ORB #4, Division of Licensing

{

SUBJECT:

"LONG TERM MECHANICAL OPERABILITY OF PURGE AND VENT VALVES" Ref: Memo, Rosztocay, EQB, to Varga, ORB #1, same subject, May 23, 1980 1.

At the request of E. Reeves, I am providing, as tabulated below, dates of licensee responses to our generic letter of September 27, 1980.

Peach Bottom 2/3 10/25/79 Hatch 1/2 11/15/79 2.

Please note that the referenced memo implies a requirement beyond the scope of our request, i.e., that all licensees should submit reports on their valve operability program. Such a report is required only for thase plants that desire to justify unlimited purging (see our letter of 11/29/78). Accordingly, this position does not apply to Peach Bottom and Hatch.

4 M-D. M. Ve relli, Project Manager Operati g Reactors Branch #4 Divisi n of Licensing cc:

E. Reeves 8007140gj

.