ML19320B601

From kanterella
Jump to navigation Jump to search
Responds to IE Bulletin 80-09, Hydramotor Actuator Deficiencies. Vendor Will Not Utilize Incorrect Spring Matl in Facility Actuators Having Greater than 3-inch Stroke.No Mod Needed for Equipment Qualification or Test Programs
ML19320B601
Person / Time
Site: Marble Hill
Issue date: 06/18/1980
From: Shields S
PSI ENERGY, INC. A/K/A PUBLIC SERVICE CO. OF INDIANA
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
References
IEB-80-09, IEB-80-9, NUDOCS 8007140506
Download: ML19320B601 (1)


Text

061d004000' sMb

,.. Af PUBLIC SERVICE INDIANA S. W. Shields Senior Vice President.

Nuclear Division June 18, 1980 U. S. Nuclear Regulatory Commission Docket Nos.:

STN 50-546 Director of Reactor Construction Inspection, 0.I.E.

STN 50-547 Washington, D. C.

20555 Construction Permit Nos.:

CPPR - 170 CPPR - 171 Mar 51e Hill Nuclear Generating Station - Units 1 and 2 NRC IE Bulletin No. 80-09

Dear Sir:

In response to IE Bulletin No. 80-09, Public Service Company of Indiana, Inc., (PSI) has determined that ITT General Controls (ITT-GC) Hydramotor Actuators are planned for use in safety-related equipment on the Marble Hill Project. However, the Original Equipment Manufacturers (OEM's) d'.scussed in the subject Bulletin will not utilize incorrect spring material in Marble Hill actuators having greater than a three (3) inch stroke.

The OEM's have used methods other thun the ITT-GC Selection Komograph to size actuators for use on safety-related equipme.it. The OEM's assure that the actuators will perform their intended functions by either factory testing the actuators to meet listed minimum force outputs or by specifying the actuators with a gross stem thrust which is several l'undred pounds more than the required thrust.

In light of the actions described above it vill not be necessary to modify equipment qualification or test programs to demonstrate functional adequacy of the Hydramotor Actuators.

If you have any questions on this report, please feel free to contact me.

Sin erely, S. W. Shields l

TDG/cg JUN 2 31980 cc: James G. Keppler E. R. Schweibinz, P. E.

J. J. Harrison P.O. Box 190, New Washington, Indiana 47162 812. 293.4441 8007140&oG