Discusses 800605 Site Visit.Nrc Personnel Found No Visual Wall Cracks Resulting from Uneven Settlements or Shrinkage During Tours of Svc Bldg,Turbine Bldg,Auxiliary Bldg & Fuel Bldg
ML19320B283
Person / Time
Site: North Anna 
Issue date: 06/24/1980
From: Nilesh Chokshi, Romney N, Rothberg O
Office of Nuclear Reactor Regulation
To: Schauer F
Office of Nuclear Reactor Regulation
References
NUDOCS 8007100140
Download: ML19320B283 (5)


Text

dvAC-o JUN 2 61980 MEETIflG SUP."ARY DISTRIBUTI0fl Docket File

  • iRC PCR G. Lear V. floonan Local PDR S. Pawlicki TIC V. Benaroya tiRR Reading Z. Rosztoc2v LBal Reading N. Haass H. Denton D. Muller E. Case R. Ballard D. Eisenhut W. Regan R. Purple D. Ross B. J. Youngblood P. Check A. Schwencer R. Satterfield Branch Chief. LBa3
0. Parr J. f1 iller F. Rosa G. Lainas W. Butler R. Vollner N. Kreger J. P. Knight R. Houston R. Bosnak T. Murohy

~

F. Schauer L. Rubenstein R. E. Jackson T. Soeis..

Project Manager A. Dromerick Branch Chief, Core Performance Attorney, OELD J. Stolz M. Rushbrook S. Hanauer 0!E (3)

4. Gamnill ACRS (16)

R. Pattson R. Tedesco F. Schroeder

0. Skovholt t4RC Particicants:

. Ba r

0. Rothber9 C. Berlinger N. Chokshi K. Kniel N. Romney G. Knianton H. Lee Branch Chief, Rel, & Risk Assessment Br.

BCC: Acolicant & Service List 80.0 710 0 /TO

[

g%g

+

o UNITED STATES

",j

[

NUCLEAR REGULATORY COMMISSION 3eq g

WASHINGTON, D. C. 20555

'gf JUN 2.; g g

    • ..=

MEMORANDUM FOR:

Franz P. Schauer, Chief, Structural Engkeering Sranch, DE THRU:

D. C. Jeng, Section A Leader, SE3/DE j P. T. Kuo, Section B Leader, SES/DE

'j FROM:

O. Rothberg, N. Chokshi, N. Rceney & H. Lee, SEB/DE

SUBJECT:

NORTH Art.*lA UrlIT 2 TRIP REPORT Members of the Structural Engineering Branch Staff, Division of Engineering, visited the North Anna Unit 2 Nuclear Generating Station on. June 5, 1980.

We met with Vepco personnel: Mr. Charles E. Sorrell, Supervisor, Civil Engineering Service. Mr. H. J. Fortune, Jr., Director of Engineering Service and S & W representative: Mr. Bob Howe.

Vepco personnel stated that they had an agreement with the NRC Project Manager of North Anna Unit 2, Mr. A. Dromerick, that Vepco would not answer'any question contained in the letter " Request for Information on the Use of Category I Masonry Walls" for North Anna Unit 2.

Instead, Vepco would submit formal

~

response to IE Bulletin 80-11 for both of North Anna Units 1 and 2 on or before July 8, 1980. They stated that although they were not in the position to answer any question at this time, they had identified all Masonry block walls in the plant and would.be happy to conduct a tour of the accessible plant areas so that we could observe the walls.

We went through the Service Building (Control Room / Computer Romm/ Mech. Equip-ment), Turbine Building, Aux. Building and the Fuel Building. We found no visual cracks of the walls as a result of uneven settlements or shrinkage.

Mr. Howe of S & W indicated that he was not the original designer. Hence, he had no knowledge of how the walls were designed and constructed.

It doesn't look that walls carry any significant loads. The walls are generally used for partition purpose or for radiation shielding and we have found no safety related piping supported by the walls. Hcwever, we have some reservations about the capability of two walls to sustain seismic loads because of their size and support conditions. The two walls in question are the wall located in the Mech. Equipment Room of the Service Building and the wall between the Aux. Building and the Fuel Building.

Vepco personnel indicated that they were in the process of accessing the safety significances and identifying the design bases of these walls as part of their responses to IE Bulletin 80-11.

. We took about_ fifteen (15) photographs for the various walls, penetrations and supports. Mr. Sorrell of Vepco has asked for copies of the photos we took but in return he premised to send us a set of lay-out drawings with all Masonry walls marked on the drawings.

D,.J Owen 0. Rothberg Structural Engineer, Section A f)m' C{

Nileshi C. Chokshi Structural Engineer, Section A

/

4 in n

b

/ orman crrney Structural Engineer, Section-8 l

)

'L en y Lee Structural Engineer, Section B cc:

A. Dromerick i

l i

."r. J. H. Ferguson Executive Vice-President - Power Operations Virginia Electric & Power Company P. O. Box 26666 Richnond, Virginia 23261 cc:

"r. Anthony Ganbaradella Clarence T. Kipps, Jr., Esq.

Of' ice cf the Attorney General 1700 Pennsylvania Avenue, N.W.

11 South 12th Street - Room 308 Washington, D. C.

20006 Richmond, Virginia 23219 Carroll J. Savage, Esq.

Richard M. Foster, Esq.

1700 Pennsylvania Avenue, N.W.

Musick, Williamson, Schwartz Washington, D. C.

20006 Leavenworth & Cope, P. C.

P. 0. Box 4579 Mr. James C. Dunstan Boulder, Colorado 80306 State Corporation Comission Commonwealth of Virginia Michael W. Maupin, Esq.

Blandon Building Hunton, Williams, Gay & Gibson Richmond, Virginia 23209 P. O. Box 1535 Richmond, Virginia 23212 Alan S. Rosenthal, Esq.

Atomic Safety and Lics'ilsing Appeal Board Mrs. June Allen U.S. Nuclear Regulatory Commission,

412 Owens Drive Washington, D. C.

20555 Huntsville, Alabama 35801 1

Michael C. Farrar, Esq.

Mrs. James Torson Atomic Safety and Licensing Appeal Board 501 Leroy U.S. Nuclear Regulatory Commission Socorro, New Mexico 87801 Washington, D. C.

20555 Mrs. Margaret Dietrich Dr. John H. Buck Route 2, Box 568 Atomic Safety and Licensing Appeal Board Gordonsville, Virginia 22942 U.S. Nuclear Regulatory Commission Washington, D. C.

20555 William H. Rodgers, Jr., Esq.

Georgetown University Law Center Atomic Safety and Licensing Boa-d Panel 600 New Jersey Avenue, N. W.

U.S. Nuclear Regulatory Commission Washington, D. C.

20001 Washington, D. C.

20555 Mr. Peter S. Hepp Mr. Michael S. Kidd Executive Vice President U.S. Nuclear Regulatory Commission i

Sun Shipping & Dry Dock Company P. O. Box 128 P. O. Box 540 Spotsivania, Virginia 22553 Chester, Pennsylvania 19013 Dr. Paul W. Purdom Mr. R. B. Briggs Department of Civil Engineering Associate Director Drexel University 110 Evans Lane Philadelphia, Pennsylvania 19104 Oak Ridge, Tennessee 37830 i

Vr. J. H. Ferguson cc:

Dr. Lawrence R. Quarles Apartnent No. 51 K endal-a t-L on gwood Kennett Square, Pennsylvania 19348 y

'M r. Irwin B. Kroot Citizens Energy Forum P. O. Box 138 ficlean, Virginia 22101 James B. Dougherty, Esq.

Potomac Alliance 1416 S Street, N.W.

Washington, D. C.

20009 W. R. Cartwright, Station Manager P. O. Box 402 Mineral, Virginia 23117 W. L. Stewart, Manager P. O. Box 315 Surry, Virginia 23883

.