ML19320B209
| ML19320B209 | |
| Person / Time | |
|---|---|
| Site: | 07106581 |
| Issue date: | 06/24/1980 |
| From: | Macdonald C NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| To: | |
| Shared Package | |
| ML19320B208 | List: |
| References | |
| NUDOCS 8007100041 | |
| Download: ML19320B209 (4) | |
Text
{{#Wiki_filter:im * -( }' -U 4-{g-Qrm NRC418 U.S. NUCLEAR REGULATORY COMMISSION g o 2 31 CERTIFICATE OF COMPl. LANCE 3g c p 7, For Radioacsive Materials Packages 1.fa) Certificate Number 1.(b) Revisinn No. 1.(c) Package Identification No. 1(d) Pages No. 1.(e) Total No. Pages 6581 12 USA /6581/B( IF 1 4
- 2. PREAMBLC 2.fal This certificate is issued m satisfy Sections 173.333a.173.394.173.335. and 173.396 cf the Cepartment cf Transportation Hazardous Materials Regulations (49 CFR 170-1P9 and 14 CFR 103) and Sections 146-19-10a and 146-10-100 of the Department of Transportation C'angerous Cargoes Regulations (46 CFR 146-149), as amended.
2.(b) The packaging and contents des:,ribed in item 5 below, rneets the safety standards set forth in Subpart C of Title 10. Code of Federal Regulations. Part 71," Packaging of Radioactive Materiais for Transport and Transportation of Raoioactive Material Under Certain Conditions!' 2.fc) This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies. including the government of any country through or into which the package will be transported.
- 3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.(a)
Prepared by (Name and address # 't.(b ) Title and identification of reoort or acosication: EXXON Nuclear Company, Inc. EAA5 Nuclear Company, Inc. application dated 2955 George Washington Way June 'i3, 1979, as supplemented. Richland, WA 99352 3ae) conerra. 71-6581 4. CONDITIONS This certificate is conditional upon the fulfilling of the reouirements of Subpart D or 10 CFR 71 as app 6icable, and the conditions specified ( m stem 5 besow.
- 5. Description of Packaging and Authorized Contents, Model Numoer, Fissile Class. Other Conditions, and
References:
(a) Packaging (1) Model Nos.: 51032-1 and 51032-la (2) Description A steel shipping contairer for fuel bundles, consisting of a strongback and fuel bundle clamping assembly, snock mounted to a i steel outer container. Minimum 3/8" thick wall, 6" x 8" x 8-1/2" long steel separators are bolted between fuel bundles. Outer container is approximately 43" diameter by 216" long. The maximum weight of the package is approximately 7,400 pounds for the Model No. 51032-1 and 8,300 pounds for the Model No. 51032-la. i (3) Drawings The Model No. 51032-1 is constructed in ar ordance with Applied Design Company Drawing Nos.: 51032-1-001, Sheet 1, Rev. H 51032-1-001, Sheet 2 Rev. F 51032-1-001, Sheet 3, Rev. F
- "~
51032-1-001, Sheet 4, Rev. F ) T 51032-1-001, Sheet 5, Rev. H i 51032-1-001, Sheet 6, Rev. F i 51032-1-001, Sheet 7, Rev. H
Page 2 - Certificate No. 6581 - Revision No.12 - Docket No. 71 -6581 59 557 (3) Drawings (continued) 51032-1-002, 2 Sheets, Rev. B 51032-1-003, Rev. 0 ~ 51032-1-004, Rev. B and Jersey Nuclear Company Drawing Nos.: JN-600, 841, Sheet 1, Rev. 2 JN-600, 843, Sheet 1, Rev. 3 JN-600, 844, Sheet 1, Rev. 2 The Model No. 51032-la is constructed in accordance with Exxon Nuclear Company, Inc. Drawing Nos.: XN-NF-303,354, Sheet 1, Rev. 0 XN-NF-303,354, Sheet 2, Rev. 0 XN-NF-303,355, Sheet 1, Rev. 0 XN-ik-303,356, Sheet 1, Rev. 0 XN-NF-303,357, Sheet 1, Rev. 0 XN-NF-303,357, Sheet 2, Rev. O "~ XN-NF-303,358, Sheet 1, Rev. 0 XN-NF-303,359, Sheet 1, Rev. 0 XN-NF-303,360, Sheet 1, Rev. 0 XN-NF-303,364, Sheet 1, Rev. 0 XN-NF-302,231, Sheet 1, Rev. 4 (b) Contents Type, form, and maximum quantity of material per package shall be as follows: (1) UO2 or unpressurized (atm pressure) Pu0 -UO2 fuel assemblies as follows: 2 Maximum No. of Radioactive Material Fissile Constituents Assemblies per a Fuel Type (kg/ Package) (kg/ Package) Package TYPE I U 362 U-235 7.6 2 l Pu 2.5 Pu 2.0 f TYPE II U 510 U-235 16.0 4 Pu 6.0 Pu 4.8 f TYPE III U 510 U-235 23.0 4 Pu 6.3 Pu 5.0 f 1 aSee Tables 2-VI thru 2-X and 12-XIV of application for the limiting physical characteristics of each fuel type.
Page 3 - Certificate No. 6581 - Revision tio.12 - Docket No. 71-6581 5. (b) (1) (continued) Maximum No. of Radioactive Material Fissile Constituents Assemblies per a Fuel Type (kg/Packaae) (kg/ Package Package TYPE IV U 240 U-235 5.0 2 Pu 1.8 Pu 1.4 f b A U 700 U-235 24.5 2 or 4 b B U 1,500 U-235 52.5 2 or b b C U 1,500 U-235 60.0 2 or 4 b D U 1,500 U-235 60.0 2 or 4 b E U 1,500 U-235 60.0 2 or 4 b F U 1,500 U-235 75.0 2 or 4 c AA U 1,100 U-235 38.5 2 bTwo fuel elements of standard length or 4 short elements of equivalent weight. cAuthorized for shipment only in Model No. 51032-la container. (2) Sintered uranium oxide pellets as Zr clad fuel rods packaged within the inner wooden container described by Exxon Nuclear Company, Inc. Drawing No. XN-301, 901, Rev.1. The package may contain up to nine (9) fuel rods having a maximum enrichment of 5.0 wt% U-235 with a maximum pellet diameter of 0.5 inches. Inert Zr rods may be additionally included. (c) Fissile Class I ana III (1) Class I Types I, II, IV, A, B, and AA described and limited in 5(b)(1). (2) Maximum number of packages (i) Types III, C, D, E, and F, assemblies l per shipment as Class III described and limited in 5(b)(1); Eight (8) packages (ii) For the contents described and limited in 5(b)(2) One (1) package
2 Page 4 - Certificate No. 6581 - Revision No.12 - Docket No. 71-6581 6. Each fuel assembly shall be enclosed in an unsealed polyethylene sheath which will not extend beyond the ends of the fuel assemblies. The ends of the sheaths shall not be folded or taped in any manner that would prevent the flow of liquids into or out of the sheathed fuel assemblies. Polyethylene shims and ethafoam pads may be used in the packaging of fuel assemblies in accorda,nce'with p. 2-6 and Table 12-XIV of the applicatipn. 7. The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b). 8. Expiration date: October 31, 1980. REFERENCES EXXON Nuclear Company, Inc. application dated June 15, 1979. Supplements dated: November 30, 1979; and June 13, 1980. FOR THE V.S. NUCLEAR REGULATORY COMMISSION l Cn(arles E. MacDonald, Chief Transportation Certification Branch l Division of Fuel Cycle and Material Safety Date: JUN 2 A 1980 i i -}}