ML19320B074

From kanterella
Jump to navigation Jump to search
Forwards Revised Final Deficiency Rept Re Spent Fuel Pool Gates
ML19320B074
Person / Time
Site: Sequoyah  
Issue date: 07/02/1980
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: Stello V
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
Shared Package
ML19320B075 List:
References
NUDOCS 8007090249
Download: ML19320B074 (1)


Text

.9 f.

TENNESSEE VALLEY AUTHORITY CH ATT ANOOG A. TENNESSEE 374ot 400 Chestnut Street Tower II July 2, 1980 Mr. James P. O'Re2.

y, Director Office of Inspectio and Enforcement U.S. Nuclear Regulato. Commission

. Region II - Suite 3100 101 Marietta Street atlanta, Georgia 10303 Jear Mr. O'Reilly:

6EQUOYAh 1.bCLEAR PLA!4T UNITS 1 AND 2 - SPENT FUEL POOL -.TES -

NCR SQN NEB 6012 - REVISED FINAL REPORT The subject deficiency was inicially reported to NRC-0IE Inspector J. D. Wilcox on May 1, 1900, in accordance with 10 CFR 50.55(e).

An interin report was submitted on May 29, 1980, and a final report was submitted on June 18, 1980. The final report has been revised to provide an administrative corrective action rather than the design cnange originally defined as the corrective ar. tion.

If you have any questions concerning thia mat:er, please get in touch witn D. L. Lambert at FTS 357-25dl.

Very truly yours, TENNESSEE huLEY AUTHORITY L. M. Mills, Manager Nuclear Regulation and Safety inclosure cc:

Mr. Viccor Stello, Jr., Director (Enclosure)

Office of Inspection and Enforcement L.S. Nuclear Regulatory Commission Washington, DC 20555

]C/7 5

~

//

8oo709034

- me, cecermem, sme;es, 3

-