ML19320A990

From kanterella
Jump to navigation Jump to search
Forwards LER 80-048/03L-0
Date released: 11/30/2019 Download: ML19320A990


LER 80-048/03L-0:on 800602,at Steady State Power,Leak Found Between Root Valve & Main Fire Header on Sensing Line PS-26- 44 During Running of SI 4.11.A.Caused by Crack in Half Inch Schedule 40 Carbon Steel Nipple Threads Due to Corrosion
ML19320A993
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 07/01/1980
From:
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19320A993 (2)
Forwards LER 80-048/03L-0
ML19320A989
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 07/01/1980
From: Calhoun J
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19320A989 (1)