ML19320A720
| ML19320A720 | |
| Person / Time | |
|---|---|
| Site: | Sequoyah |
| Issue date: | 06/26/1980 |
| From: | Mills L TENNESSEE VALLEY AUTHORITY |
| To: | James O'Reilly NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
| Shared Package | |
| ML19320A721 | List: |
| References | |
| NUDOCS 8007020543 | |
| Download: ML19320A720 (1) | |
Text
.
TENNESSEE VALLEY AUTHORITY CH ATTANOOGA, TENNESSEE 37401 400 Chestnut Street Tower II June 26, 1980 Mr. James P. O illy, Director Office of Inspec on and Enforcement U.S. Nuclear Regul ory Cosuaission Region II - Suite 3 0 101 Marietta Street Atlanta, Georgia 3030
Dear Mr. O'Railly:
SEQUOYAH NUCLEAR PLANT UNIT 2 - SAFETY-RELATED CABLE INSIDE CONTAINMENT NOT QUALIFIED - NCR SQN QEB 8002 - FLNAL REPORT The subject deficiency was initially reported to NRC-0IE Inspector M. J. Gouge on March 25, 1980, in accordance with 10 CFR 50.55(e).
An interim report was submitted on April 24, 1980.
Enclosed is our final report.
If you have any questions concerning this matter, please get in touch with D. L. Lambert at TTS 857-2581.
Very truly yours, TENNESSEE VALLEY AUTHORITY L. M. Mills, Manager Nuclear Regulation and Safety Enclosure cc:
Mr. Victor Stello, Jr., Director (Enclosure)
Office of Inspection and Enforcement t
l U.S. Nuclear Regulatory Commission Washington, DL 20555 1
\\
8007020 $ &
3 b
An Equal Opportunity Employer