' ' C,. f[7# 78 REGULATORY INFORMATION DISTRIBUTION SYSTEM (RIDS)
DISTRIBUTION FOR INCOMING MATERIAL 50-312 REC:
ORG: MATTIMOE J J DOCDATE: 05/11/78 NRC.
SACRAMENTO MUN UTIL DIST DATE RCVD: 05/24/78 DOCTYPE: LETTER NOTARIZED: NC COPIES RECEIVED
SUBJECT:
LTR 1 ENCL 1 FORWARDING SUPPLEMENT TO SUBJECT FACILITY"S OPERATIONS REPT FOR THE YEAR 1977, CONSISTING OF RESULTS OF THE STEAM GENERATOR TUBE INSERVICE INSPEC.
PLANT NAME: RANCHO SECO (SMUD)
REVIEWER INITI AL:
XJM DISTRIBUTOR INITI AL: pL,,
- oco************ DISTRIBUTION OF THIS MATERIAL IS AS FOLLOWS ******************
MONTHLY OPERATING REPORT FOR GRAY BOOK PREPARATION.
(DISTRIDUTION' CODE ACO3)
FOR ACTION:
BR CHIEF REID**W/2 ENCL bG F INTERNAL:
LE**W/E NRC PDR**W/ ENCL MIP 6R (u,iAuu~ m,2 ENCL EXTERNAL:
LPDR'S SACRAMENTO, CA**W/ ENCL REGION V**W/ ENCL TIC **W/ ENCL NSIC**W/ ENCL BNL(NATLAB)**W/ ENCL ACRS CAT B**W/O ENCL
/
DISTRIBUTION:
LTR 11 ENCL 11 CONTROL NBR:
.v SIZE: 1P+1P COR 07*****************************
THE END
- (
8004010 7 2 3
o O
$SMun EEMTgggEE0PY SACRAMENTO' MUNICIPAL UTILITY DISTRICT O 6201 S Street. Box 15830, Sacramento, California 95813; (916) 452 3211 May 11, 1978 Director Office of Inspection and Enforcement
~
U.S. - Nuclear Regulatory Commission Washington, D. C. 20555 Re: Operating License DPR-54 Docket No. 50-312 Plant Operations Report - 1977
Dear Sir:
On March 14, 1978, the Sacramento Municipal Utility District submitted its report of plant operations for the year 1977, in accordance with Tech-nical Specifications Section 6.9.5.A.
The report as issued, inadvertantly did not include the results of the Steam Generator Tube Inservice Inspectica completed during that time period.
In accordance with Technical Specifications Section 4.17.5b, the Sacra-mento Municipal Utility District hereby submits the attached supplement to the Plant. Operations Report - 1977.
Respectfully, 0
.v
.G. Mattimoe Assistant General Manager and Chief Engineer JJM:RWC:jlk Enclosure cc: NRC, Region V Office of Management Information
& Program Control
.? '
' A N -- E L E C T R I C SYSTE M S E RVIN G MORE THAN 600,000 IN THE HEART OF C A LIF O R N I A
)
s-eq r
SUPPLEMENT TO PLANT OPERATIONS REPORT - 1977 DESCRIPTION A-0TSG B-0TSG No. of Tubes Inspected 9.000% = 1391 Tubes 3.345% = 517 Tubes No. of Tubes Plugged 8
0 L; cation of Indications All indications are near the Upper Indications (30-40%) found at Tube Support Plate (15th).
15th support plate, thought to Thought to be caused by wear.
be a pit, tube not plugged.
Location of Plugged Tubes 7 of the plugged tubes are N/A adjacent to the " Lane Row" within 11 tubes of the periphery.
The 8th is 6 rows from the " Lane Row" and within 2 rows of the periphery, Gen:ral Description of Where Tubes near the lane row, on the The Lane Row, periphery near Incpect d Tubes are Located periphery and in the 7-W quadrant.
the Lane Row, tube support The X-W quadrant was chosen to rods, near the circle of minimize the number of Templates missing tubes 180* from lane to be installed and therefore the row, near periphery of W-Y exposure to personnel and still Axis. These locations were sample those areas of known chosen to minimize exposures conce rn.
and still eample those areas of known concern.
Typ: of Inspection Mixture of 100% inspection and All tubes 100%.
partial inspection down to 9th support plate allowed per the Rancho Seco Technical Specifica-tions, Section 4.17.2(c).
I