ML19319D273

From kanterella
Jump to navigation Jump to search
Summary of 780609 Meeting W/B&W Owners Group Re Permanent Solution to Small Break Problem.Attendee List & Valve Diagram Encl
ML19319D273
Person / Time
Site: Arkansas Nuclear, Crystal River, Rancho Seco, Crane  
Issue date: 06/16/1978
From: Vissing G
Office of Nuclear Reactor Regulation
To:
Office of Nuclear Reactor Regulation
References
NUDOCS 8003130911
Download: ML19319D273 (3)


Text

R, g,

8 UNITED STATES g

/

8~

NUCLEAR REGULATORY COMMisslON

,7

{*'

WASHIN'iTON. D. C. 20555 E

O s.,-...../

7_

Dockets Nos. 50-313 / '

50-302v

~50-289 and 50-312 LICENSEES:

Babcock & Wilcox Owner's Group consisting of Arkansas Power and Light Company, Florida Power Corporation, Metropolitan Edison Company and Sacramento Municipal Utility District FACILITIES: Arkansas Nuclear One - Unit 1, Crystal River Unit No. 3, Three Mile Island 1 and 2, and Rancho Seco fiEETING WITH B&W OWNER'S GROUP CONCERNING PERMANENT SOLUTION TO SMALL BREAX PROBLEM, JUNE 9, 1978 Introduction is a list of attendees.

The purpo.e of the meeting was to discuss a proposed permanent solution to the small break problem.

The proposed solution to the small break problem consisted of (1) opening the cross over valve, (2) powering the motor operated injection valves from either division through a manual actuated (from the control rooms) transfer switch (attachment 2).

Conclusion The staff advised that the proposed solution was not acceptable as a permanent solution because (1) operator action was required within 10 minutes of the break and (2) of a single failure at the transfer switch.

However, the proposed solution could be acceptable as an interim solution until the permanent solution was accepted if the single failure could be eliminated.

f./

4 q

Guy VissiD9rttoject Manager Operating Reactors Branch #4 Division of Operating Reactors 8008130 h

,s 4r

r--

O e-*

LIST OF ATTENDEES MEETING _OF 6/9/78 Name Organization S. C. Rhow NRR/ DOR /PSB Paul Shemanski NRR/ DOR /PSB J. Ted Enos AP&L Donald A. Rueter AP&L Henry Bailey B&W W. E. Potts Met Ed Carl H. Berlinger NRR/ DOR /RSB Leonard 01shan NRR/ DOR /RSB

~

Gerald B. Zwetzig NRR/ DOR / ORB #4 Harley Silver NRR/DPti Chris Nelson NRR/ DOR /0RBf4 Michael E. Ober Gilbert Assoc. for FPC R. W. Reid NRR/00R/C-ORBd4 Q. B. DuBois Florida Power Corp.

G. Vissing NRR/00R/0RB#4 4

b A

N A

'O

/

so N

\\)

/

r 9

%i

,s j

o o-

[

g 3

m

\\

n t--__J

_(.,g t

o

--< ~

7 a

o v

M m

k I'J 01:

m g

gb

-c--o e

a g 'v 4m e., o

)E v}k 3d a

-?

q s

t) g O

M g}$

e 513 4 3

\\

J 4

g

)

hec x -

kd E

I i

x%

0 3

I A b 3A DS n

% a vu t

4 v

& }(

%.3 d v

ay

%3 Tog Rk s

9 2 wuu

%4

%s Q9M w

1 Q

'o T

iv i

e I

ym i

k I

q

. 1 l

i o e

5 l-1 V

Mt.- - 4 0-u i

L-~~l i

l oM

[

2A*WAY

.