SEp 2 61974 Docket No. 50.-346

!. Peltier, Pro.!ect Manager, Light Water Reactors tranch 2-3, L DAVIS-BESCE I OPERATOE Rtt}UALITICATIdN PROGR.L't We have reviewed the Davis-Besse I FSA2 in which the operator requalification program is described. Based on our review, ve have concluded that the revisions indicated in Attach =ent A are necessary to bring the prograss into conformance with previously approved requalification programs. Attachment 3 contains a list of seceptable control manipulations for neeting the 10 reactivity control wnipulations required in paragraph 3a of Appendix A to 10 C7R Part 55.

In order that we :say complete our review, please recuent the applicant to submit a revised program within thirty days of the date of this letter.

@5tCINM. SICATD By P. F. COLLINS Paul F. Colline, Chief Overator Licensing Branch Directorate of Licensing

Enclosures:

1.

Attachment A 2.

Attachment B cc:

A. Schwencer DISTRIBUTION:

OLB R/F Central Files DO g

JJHolman n

O o JLl n

D ~9~T

~'

GS-b m,, Il/yt &

/

OLSe:D /

OLBt o nc = +-

. g. ;..

fJBWnan:dif,

.......Ilins,gr'.

.u.....

.'_9 h d l.7_4_ _.I'9/b /70 o us e-Pens AIC.318 (Rev. 9 S)) AACM 0240 W u. s. eovsaw.esar enemnne ornces sere.sa see

}[

8 0 02190 77f F

4.

ATTACHMENT A DAVIS-BESSE I DOCKET No. 50-346 1.

The program should indicate that upon completion of the program, the program will be promptly followed, pursuant to a continuous schedule, by successive requalification programs.

2.

The reactivity manipulations for which credit will be taken must be specified.

An acceptable list of manipulations for PWR's appears in Attachment B.

Additionally, a statement must be included that indicates an effort will be made to have an individual perform a co=bination of manipulations during any two year requalification program.

3.

The applicant should provide the details of the implementation of the on-the-job training.

Specifically, the information should include the frequency of procedure reviews, who will conduct the evaluation and the documentation that will be maintained. Sufficient information should be included to show how the requirements of Paragraphs 3b, 3c, 3d and 4c of Appendix A of 10 CFR Part 55 will be met.

4.

The requalification program must provide for an annual written examination cercarable to an AEC exanination censistent vith the type of license held.

In addition, the program must provide a grade criterion for determining that an individual should participate in an accelerated requalification program pursuant to Paragraph Ge of Appendix A.

A grade of less than 707. overall on the annual written examination has been established as requiring mandatory participation in an accelerated requalification program.

The program should contain a provision that an individual enrolled in an accelerated requalification program shall not perform licensed duties until he has successfully completed the accelerated program.

The scope and duration of the accelerated program should be based on the individual's denonstrated deficiencies.

5.

The schedule of lectures should be orovided. The minieu= nunker of lectures in any calendar year should not be less than six, evenly spaced throughout the year and taking into consideration heavy vacation periods and infrequent operations such as, refueling i

periods. Lectures may be deferred due to unanticipated shutdowns.

However, these lectures should be conducted at a later date.

Facility.

management may elect to have all licensed individuals attend every lecture.

An alternative to this is to use the results of the annual written examination to develop the lecture series and attendance for the following year.

If this latter method is used, the requalification program should contain a grade criterion for, exemption from attendance i

i l

n

. at a given lecture. "The minimum grade acceptable for exemption from attendance at a particular lecture is 80% in that category of the examination. The program should state the method to be I

used and include the appropriate criteria.

6.

The requalification program must include a commitment to administer periodic written examinations pursuant to Paragraph 4b of Appendix A.

j Further, it has been established in approved programs that an individual i

scoring less than 80% on a periodic written examination will be required l

to undergo remedial training in the subject material.

Thf, criterion must also be included in your program.

l 7.

The program should specify the extent to which licensed staff members will participate in the requalification program.

As a minimum the individuals should:

1.

be administered the annual written examination and attend the lecture series based on the results thereof, if that is the al-ternative chosen, 2.

manipulate the controls or supervise the munipulations of the controls through 10 reactivity chances, 3.

systematically review the contents of a.1 abnormal and emergency procedures on a regularly scheduled basis, 4.

systematically review design changes, procedure changes and facility license changes, and 5.

be systematically evaluated regarding actions to be taken during simulated abnormal and emergency conditions by a walk-through of the procedural steps of the procedure.

8.

Records of the requalification program shall be maintained to document each licensed operator's and senior operator's particiration in the requalification program. The records shall contain copics of written examinations administered, the answers given by the licensee, results of evaluations, documentation of the review of abnormal and emergency procedures and of changes to procedures, facility design and facility license and documentation of any additional training administered in areas in which an operator or senior operator has exhibited deficiencies.

e

.m ATTACHMENT 5 ACCEPTABLE REACTIVITY MANIPULATIONS FOR A PWR DAVIS-BESSE I DOCKET NO. 50-346 l

1.

Startup to the point of adding heat 2.

Orderly. shutdown 3.

Manual control of S/G 1evels during sr.artup and shutdown 4.

Operation of EHC in manual during startup 5.

Boration during power operation 6.

Dilution 7.

Operation of manipulator crane during refueling over the core.

8.

Any significant ( '>10%) power charges in manual rod control 9.

Manual rod control prior to and during generator synchronization.