Text
_ _ _.
v V
s MU S GCVERNMENT en,Nri OFFrCE 1775.G =a7"6 a
f 8 #C*A DATE OF Docu' r *7 QATE RECE'vE:':
NO Lowell.c.. Roe 300 Madissa Avenue 1-9 6
3-11-70 NRR-766 Toledu, Ci. :
iF' u~
vEvo Erar C r.. E.
X TO OR ' G CC OTHER B.C. Rusche X
g AcroN NE:Es:-
g CcNCu.. ENC,
- 0. r E. N5.E o w O 9E>N/v "t
"L.)
r.O Act'ON NECESSA A v COvvENr sv J
v CLA55 5 PCSf C5 5 5CE psLE :CCE nEG NO DE SCp t*' CN wie se Wess.e eon l
- E8 ERAE3 r0 DATE aECtevED ev CA?E Request for consideration to allcw l
the Davis-Besse to operate with l R. Boyd 3-11-76 c
tha existing installed Emergency l ie DLqsel-Generator Fuel Oil Storagei
} p(_)O j[,,./{
gg, i
and Transfer System in service
/
1 E NC LO 5Ue E '.
e
/
}
until the new systen has beeni Coov tc:
. 1 completed.
- 4 g,.- bg@<,
y//3 e
B.C. Rusche
{
l I.
E.G. Case J.R. Miller PEW 4RE$
I I
pt,p,e y,, m :
- h a f f on ma rRut R. Heine:ilan l
n Alc a re turn o r'iMDa-
$,7 [ ;n f.tr al ticket to WMrorr e.en H. Denton i', " '
V. Stello
.,a V " WCLE AA DE 3 A A!CA v CCUMK5 ON s r.n..
- ,e~
Mall CONTROL FOR*A I"
l_..
-y. e.
,~..
u a, :..
. L., * ~!. ~ f.... ' ' :-v: s. ; ; s:.'l. p :: ; ',
f _.~ ' ~
.*- % < =..:
.f *'
'.'.~-
~. '. *. I.f ' - :
' ~
- q.
....w
.... ~
A.
w........., %.__._
z n a _
~:.-...
~
1
~,
._ y
' L.
l
. s...
-.. ',.m u.-
.e e e
,. ~..;. t -. ~ m
- ?
_ r (3.%.;,,...
w lI l
il l
I I
l s001300 f-l t
i
s S
/
t e
e TOLEDO E[31EiC)rd Docket No. 50-346 LOWELL E. RCE v,c. %....
Facmt es :: eve'ocment 14131 259-5242 March 8, 1976 Mr. Benard C. Rusche, Director Office of Nuclear Reactor Regulation United States Nuclear Regulatory Commission Washington, D.C.
20555
Dear Mr. Rusche:
The design of the Emergency Diesel-Generator Fuel Oil Storage and Transfer System has been changed recently by Revision 17 to the Davis-Besse Nuclear Power Station FSAR to provide each of the two diesel-generators with seven day capacity on-site storage which is missile protected, seismic category I and Q-listed.
Because of long lead times for delivery of the pumps and tanks, the new system is not expected to be operational until June, 1977; full power operation is expected by the end of 1976 based on currently scheduled hot functional testing beginning June 7, 1976.
The system which was described in the FSAR prior to Revision 17 will be slightly modified and will be operational prior to fuel load.
The slight =cdifications will consist of additional flanged connections to allow for switching to the new system without welding or cutting. Welding or cutting on a tank or pipe containing diesel fuel is forbidden by OSRA regulations.
As recommended by the NRC staff in a meeting with the Applicant on January 29, 1976, the Applicant hereby requests consideration to allow the Davis-Besse Nuclear Power Station Unit I to operate with the existing installed Emergency Diesel-Generator Fuel Oil Storage and Transfer System in service until the new system has been completed.
The Applicant will keep NRC staff informed of any changes to the expected completion date.
Yours very truly, mj e/1 THE TCLECC ECISON COMPANY ECISCN PLAZA 300 MACISCN AVENUE TCLECC. CH!C 43652