ML19319B643

From kanterella
Jump to navigation Jump to search
Forwards RO NP-33-77-44
Date released: 11/29/2019 Download: ML19319B643


RO NP-33-77-44:on 770729,indication Variation on Level transmitters,LT-SP9A6 & LT-SP9A7,found Greater than Allowed. Caused by Leaking Vent Valves in Transmitter.Valves Tightened & Level Indication Returned to Normal
ML19319B752
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 08/23/1977
From: George T, Lingenfelter J
TOLEDO EDISON CO.
To:
References
Download: ML19319B752 (2)
Forwards RO NP-33-77-44
ML19319B642
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 08/23/1977
From: Roe L
TOLEDO EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19319B642 (1)