ML19318D121

From kanterella
Jump to navigation Jump to search
Forwards LER 80-029/01T-0
Date released: 11/28/2019 Download: ML19318D121


LER 80-029/01T-0:on 800624,during Mode 3 Operation,Power Operated Relief Valve PCV-2456 Opened Inadvertently & Failed to Reclose.Caused by Cocked Bearing in Valve Actuator. Upstream MOV-2535 Closed to Terminate Relief Flow
ML19318D126
Person / Time
Site: North Anna 
Issue date: 07/02/1980
From: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19318D126 (2)
Forwards LER 80-029/01T-0
ML19318D120
Person / Time
Site: North Anna 
Issue date: 07/02/1980
From: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19318D120 (1)