ML19318D072

From kanterella
Jump to navigation Jump to search
Responds to NRC Re TMI-2 Related Requirements. Items I.A.1.3,I.A.3.1,I.C.5,II.K.3 & III.D.3.4 Currently Under Review for TMI-1.Items for TMI-2 Will Be Reported Under Separate Cover
ML19318D072
Person / Time
Site: Crane  Constellation icon.png
Issue date: 06/30/1980
From: Herbein J
METROPOLITAN EDISON CO.
To: Eisenhut D
Office of Nuclear Reactor Regulation
References
TLL-286, NUDOCS 8007070294
Download: ML19318D072 (2)


Text

_ _ _ _ _ _ _ _ _

n Metropolitan Edison Company Post Office Box 480 e

Middletown, Pennsylvania 17057 717 944-4041 Writer's Direct Dial Number June 30, 1980 TLL 286 Of fice of React.or Regulation Attn: Darrell G. Eisenhut, Director U. S. Nuclear Regulatory Commission Washington D.C.

20555

Dear Sir:

Three Mile Island Nuclear Station, Unit I and II (TMI-l and T'JI-2)

Operating License Nos. DPR-50 and DPR-73 Docket Nos. 50-289 and 50-320 TMI-2 Related Requirements In response to your letter of May 7, 1980 concerning the five additional items, Metropolitan Edison Company is continuing its review in detail of each of these items for TMI-I:

ITEM TITLE

RESPONSE

I.A.l.3 Shift Manning Met-Ed is currently awaiting receipt from the NRC of re-quirements for implementation in the form of " Separate Cor-respondence" discussed in the NRC's May 7, 1980 letter before completing our evaluation of this issue.

I.A.3.1 Revise Scope and Met-Ed has revised the Operator Criteria for requalification program to 1

License Exami-conform to the requirements nations of the NRC's March 28, 1980 letter.

The associated pro-cedure has been revised and is under review.

t.c.5 Procedures for Met-Ed is continuing to review Feedback of Opera-this item and will respond by ting Experience t1 August 1, 1980.

Plant Staff Ol 5

IO 8 00707o 2 Metropci: tan Ed son Company is a Me...oer of the General Puthe UtAt'es System

D. G. Eie nhut TLL 286 ITDi TITLE

RESPONSE

II.K.3 Final Recommendations-of Met-Ed-is continuing to B&O Task Force (Measures review this item and will to Mitigate Small Break respond by August 1, 1980.

Loss of Coolant Accidents

'and. Loss of Feedwater Ac-cidents)

III.D.3.4

' Control Room Habitability Met-Ed is continuing'to review this item and will t

respond by August 1, 1980.

With regard to review of the above items for TMI-II, we intend to respond to these items under separate cover.

Sincerely, h -

J. G. Herbein Vice President TMI-I JGH:DHJ:Ima ec:

J.

T.' Collins B. J. Snyder B. H. Grier R.

W.' Reid H.-Silver D. Dilanni

....