ML19318D043

From kanterella
Jump to navigation Jump to search
Responds to NRC Requesting That All Licensees Amend Tech Specs So That Definition of Term Operable Would Be Consistent W/Nrc Sts.Revision Will Require at Least 90 Days
ML19318D043
Person / Time
Site: Arkansas Nuclear  Entergy icon.png
Issue date: 07/01/1980
From: Trimble D
ARKANSAS POWER & LIGHT CO.
To: Clark R, Reid R
Office of Nuclear Reactor Regulation
References
1-070-03, 1-70-3, 2-070-02, NUDOCS 8007070253
Download: ML19318D043 (2)


Text

p 5 :,a,

ARKANSAS POWER & LIGHT COMPANY POST OFFICE BOX 551 LITTLE ROCK, ARKANSAS 72203 (501)371-4000 July 1, 1980 1-070-03 2-070-02 Director of Nuclear Reactor Regulation ATTN: Mr. Robert W. Reid, Chief Operating Reactors Branch #4 Division of Licensing U,. S. Nuclear Regulatory Comission Washington, D. C.

20555 Director of Nuclear RegulationV ATTN: Mr. Robert A Clark, Chief Operating Reactors Branch #3 Division of Licensing U. S. Nuclear Regulatory Commission Washington, D. C.

20555

Subject:

Arkansas Nuclear One - Units 1 & 2 Docket Nos. 50-313 and 50-368 License Nos. DPR-51 and NPF-6 Standard Technical Specifications Definition of Operable (File:

1511.1, 2-1511.1)

Gentlemen:

Your letter of April 10, 1980, to all power reactor licensees requested that each licensee amend their Technical Specifications such that their definition of operable would be consistent with that of the NRC's Stan-dard Technical Specification.

Due to the large number of high priority issues currently being actively pursued, we have been unable to comply with your request. However, within the next 45 days we plan to submit, for your review, the revised AN0-2 Technical Specifications with the

. Standard Technical Specification definition of operable incorporated.

The ANO-1 revised Technical Specifications will then follow, being sub-mitted, for your review, within 90 days.

The ANO-1 Technical Specifications are not in the Standard Technical Specification fomat.

In order to incorporate the subject definition of operable and to' take exception to it' where appropriate, a substan-tial effort will be required.

Therefore, the Technical Specification revision for ANO-1 will require at least 90 days to prepare.

8007070as3 MEMBEA MOOLE SOUTH UTIUTIES SYSTEM

4 a

i I'

1-070-03 2-070-02 July 1,1980 Presently, both the AN0-1 and AN0-2 Technical Specification definitions of operable meet the basic intent of the standardized definition.

Therefore, the operation of ANO-1 and ANO-2, using the present definition of operable, will pose no undue risk to the safety and health of the general public.

Should you have any conments on our proposed course of action to incorpo-rate your proposed revision, please coistact us.

Very truly yours, b & [. Y David C. Trimble Manager, Licensing DCT:DEJ:skm 4