ML19318C485

From kanterella
Jump to navigation Jump to search
Forwards LER 80-016/03L-0
Date released: 11/28/2019 Download: ML19318C485


LER 80-016/03L-0:on 800529,during Instrument Calibr, Instrument Was Dropped on Trip Throttle Valve Linkage, Tripping Valve & Making Pump Inoperable for 3 Minutes. Caused by Personnel Error
ML19318C494
Person / Time
Site: Prairie Island Xcel Energy icon.png
Issue date: 06/27/1980
From: Hunstad A
NORTHERN STATES POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19318C494 (1)
Forwards LER 80-016/03L-0
ML19318C484
Person / Time
Site: Prairie Island Xcel Energy icon.png
Issue date: 06/27/1980
From: Mayer L
NORTHERN STATES POWER CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19318C484 (1)