sb-M I SifLll>

Colt industries Fairbanks Morse Engine Division 701 Lawton Avenue Beloit Wisconsin 53511 608/364 4411 June 26, 1980 Office of Inspect

& Enforcement U. S. Nuclear gulatory Commission 799 Roosev3 Road Glen Ellyn, Ill 60137 Atte ion: Mr. James G.*Keppler, Director, Region III p

dbject: Colt Industries-Fairbanks Morse Engine Division

/

Emergency Diesel Generators South Carolina Electric & Gas Co.-Summer Station January 14,1980 Part 21 Report-Failed Engine Thrust Bearing Supplement No. 3-Duquesne Light Co., Beaver Valley II Gentlemen:

We have completed our inspection of the crankshaft thrust bearings on the two Diesel Generators for Duquesne Light Co., Beaver Valley Unit II.

The plugs were properly installed in both units. The units are free of the reported potential defect.

A copy of this report is being forwarded to the utility involved via the A/E.

We will report our findings on the remaining suspect units as the inspections are made, prior to their initial operation.

Very truly yours, ll V3

. M. Moriarty MANAGER UTILIT S LES JMM:jc cc: South Carolina Electric & Gas Co.

P. 0. Box 764 Columbia, South Carolina 29218 Attention: Mr. Dan Nauman Manager, Quality Assurance & Security 0.8 U. S. Nuclear Regulatory Commission 5