Forwards Cycle 5 Startup Test Results
ML19318B662
Person / Time
Site: Quad Cities 
Issue date: 06/19/1980
From: Janecek R
COMMONWEALTH EDISON CO.
To: Ippolito T
Office of Nuclear Reactor Regulation
Shared Package
ML19318B663 List:
References
NUDOCS 8006270273
Download: ML19318B662 (1)


Text

_

O) c One First National Plaza, Chicago, filinois (g O Address Reply to: Post Offica Box 767 N

Chicago, Illinois 60690 June 19, 1980 Mr. T. A.

Ippolito, Chief Operating Reactor Branch 2 Division of Licensing U.S. NRC Washington, DC 20555

Subject:

Quad Cities Station Unit 2 Summary Startup Test Report for Reload No. 4 (Cycle 5)

NRC Docket No. 50-265

Dear Mr. Ippolito:

In accordance with previous commitments, enclosed for your review is the Quad Cities Nuclear Power Station Unit 2, Cycle 5, Startup Test Results summary report.

One (1) signed original and thirty-nine (39) copies of this letter and enclosure are provided for your use.

Very truly yours, W

ww Robert F.

Janecek Nuclear Licensing Administrator Boiling Water Reactors 4666A 8006270273 t