ML19318A552

From kanterella
Jump to navigation Jump to search
Forwards LER 80-032/03L-0 & LER 80-033/03L-0
Date released: 11/28/2019 Download: ML19318A552


LER 80-032/03L-0:on 800515,both Chlorine Detectors Were Inoperable.Caused by Plastic Strip Lodged in B Detector & Cracked Diaphragm in a Detector.Strip Removed & B Made Operable on 800515.Pump Replaced & a Operable on 800516
ML19318A569
Person / Time
Site: Farley 
Issue date: 06/13/1980
From: Hairston W
ALABAMA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19318A569 (1)
LER 80-033/03L-0:on 800516,1-2A Diesel Generator Declared Inoperable Due to Speed Control Failure.Caused by Personnel Error in Installing Dc Recorder Which Blew Ac Fuse.Fuse Replaced,Personnel Instructed
ML19318A560
Person / Time
Site: Farley 
Issue date: 06/13/1980
From: Hairston W
ALABAMA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19318A560 (1)
Forwards LER 80-032/03L-0 & LER 80-033/03L-0
ML19318A551
Person / Time
Site: Farley 
Issue date: 06/13/1980
From: Clayton F
ALABAMA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19318A551 (1)