ML19318A502
| ML19318A502 | |
| Person / Time | |
|---|---|
| Issue date: | 04/11/1980 |
| From: | Potapovs U NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| To: | Peshek C AMERICAN INSTITUTE OF STEEL CONSTRUCTION, INC. |
| Shared Package | |
| ML19318A503 | List: |
| References | |
| REF-QA-99900650 NUDOCS 8006230233 | |
| Download: ML19318A502 (2) | |
Text
__
=
v p 400,,'o, UNITED STATES NUCLEAR REGULATORY COMMISSION
- 1 REGloN IV E !
S 611 RYAN PLAZA DRIVE, SUITE 1000 7 f' f '* I
~
...E ARLINGTON, TEXAS 76012 r.,4 11 APR M80 Docket No. 99900650/80-01 American Institute of Steel Construction, Inc.
Atta:
Mr. Charles Peshek, Jr.
Director Quality Certification The Wrigley Building 400 North Michigan Avenue Chicago, Illinois 60611 Gentlemen:
This refers to the QA program inspection conducted by Ross L. Brown of this office on March 24-26, 1980, of your facility at Chicago, Illinois, and to the discussions of our findings with you at the conclusion of the inspection.
Areas examined during the QA program inspection and our findings are discussed in the enclosed report. Within these areas, the inspection consisted of an examination of procedures and representative racords, interviews with personnel, and observations by the inspector.
Within the scope of this inspection, we found no instance where you failed to mcet the commitment (s) of your Topical Report No. FCTPN-78.
In accordance with Section 2.790 of the Commission's " Rules of Practice,"
Part 2, Title 10, Code of Federal Regulations, a copy of this letter to-gether with the enclosed inspection report will be placed in the Commission's Public Document Room.
If this report contains any information that you believe to be proprietary, it is necessary that you make a written appli-cation within thirty (30) days to this office to withhold such information from public disclosure. Any such application must include a full statement of the reasons on the basis of which it is claimed that the information is proprietary, and should be prepared so that proprietary information ideutified in the application is contained in a separate part of the docu-ment.
If we do not hear from you in this regard within the specified period, the report will be placed in the Public Document Room.
8 00'82 8 0 U3
5 American Institute of Steel Construction, Inc.
2 Should you have any questions concerning this inspection, we will be pleased to discuss them with you.
Sincerely, Uldis Potapovs, Chief Vendor Inspection Branch
Enclosure:
Inspection Report No. 99900650/80-01 4
4 l
, _ -. _