O power EI Company TD V
tj o.n.r. ome..: nia w..e uicsg.n 4..no., soca.on, usema.o.eaos. 4,.. coa. sir 7es. esso June 17, 1980 Mr James G Keppler Office of Inspection and Enforcement Region III US Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, IL 60137 DOCKET 50-155 - LICENSE DPR BIG ROCK POINT PLANT - RESPONSE TO IE BULLETIN 80-09, HYDRAMOTOR ACTUATOR DEFICIENCIES IE Bulletin 80-09, Hydramotor Actuator Deficiencies, dated April 17, 1980 required a review to see if any Model AH-90 or Model NH-90 series hydramotor actuators were installed in any safety-related systems.
This review demonstrated that neither the AH-90 nor NH-90 hydramotor actuators were installed in any safety-related systems at the Big Rock Plant.
David P Hoffman (Signed)
David P Hoffman Nuclear Licensing Administrator CC Director, Office of Nuclear Reactor Regulation Director, Office of Inspection and Enforcement NRC Resident Inspector Director of Reactor Construction, OIE
\\
$0 1roose 003%
Q
-