ML19318A251

From kanterella
Jump to navigation Jump to search
Forwards Trip Rept & Summary of 800424 & 25 Meeting W/ Sargent & Lundy in Chicago,Il Re Soil Structure Interaction
ML19318A251
Person / Time
Site: LaSalle  
Issue date: 06/05/1980
From: Bournia A
Office of Nuclear Reactor Regulation
To: Youngblood B
Office of Nuclear Reactor Regulation
Shared Package
ML19318A252 List:
References
NUDOCS 8006190089
Download: ML19318A251 (3)


Text

_

MEETING SU N RY DISTRIBUTION Docket File G. Lear NRC PDR-V. Noonan Local PDR-S. Pawlicki JIC V. Benaroya NRR Reading Z. Rosztoczy LB#1 Reading

. W. Haass H. Denton D. Muller E. Case R. Ballard D. Eisenhut W. Regan R. Purple D. Ross B. J._Youngblood P. Check A. Schwencer R. Satterfield Branch Chief, LB#3

0. Parr J. Hiller F. Rosa G. Lainas W. Butler.

R. Vollmer W. Kreger J.-P. Knight R. Houston R. Bosnak T. Murphy F. Schauer L. Rubenstein R. E. Jackson T. Speis Project Manager A. Bournia Branch Chief, Core Performance Attorney, OELD J. Stolz M. Rushbrook S. Hanauer OIE (3)

N. Gammill ACRS (16)

R. Mattson R. Tedesco F. Schroeder D. Skovholt M. Ernst R. Baer C. Berlinger K. Kniel G. Knichton Branch Chief, Rel, & Risk Assessment Br.

BCC: Applicant & Service List i

JUN 5 1980 L80061900d 4-t

'o

/

UNITED STATES

[N i'

NUCLEAR REGULATORY COMMISSION j,) I N j

WASHINGTON, D. C. 20555

  • N _ / /

o s, v f JUN 5 1980 Docket Nos. 50-373 50-374 MEMDRANDUM FOR:

B. Joe Youngblood, Chief Licensing Branch No. 1 Division of Licensing FROM:

Anthony Bournia, Project Manager Licensing Branch No. 1 Division of Licensing

SUBJECT:

TRIP REPORT TO SARGENT AND LUNDY'S CHICAGO OFFICE TO DISCUSS LASALLE'S S0IL-STRUCTURE INTERACTION Enclosed are the minutes of meetings held with Sargent & Lundy at their Chicago offices on April 24 and 25,1980, to discuss the procedures used for soil-structure interaction analysis for the LaSalle County Station.

S. Chan, the author of the report, was the designated NRC representative for the meeting.

{l,sti.e 3 ib s ~~ ~ >~ '

~

Anthony Bournia, Project Manager Licensing Branch No. 1 Division of Licensing

Enclosure:

As stated I

l l

l

i.

Mr. D. Louis Peoples Director of Nuclear Licensing Commonwealth Edison Company P. O. Box 767 j

Chicago, Illinois 60690 cc:

Richard E. Powell, Esq.

Isham, Lincoln & Beale One First National Plaza 2400 Chicago, Illinois 60670 Dean Hansell, Esq.

Assistant Attorney General State.of Illinois 188 West Randolph Street Suite 2316 Chicago, Illinois 60601 Mr. Roger Walker, Resident Inspector V. S. Nuclear Regulatory Commission -

P. O. Box 737 Streator, Illinois 61364 4

+

1 JUN 5 1980 e..,

.w--