LOUISIANA 442 ocunonce Srneer POWER & LIGHT p o. Box 6008
- NEW CALeANS. LOUISIANA 70174 (5041 366-2345
[$ui$ErsM June 13,1980
- a. uswen vce President-power producten LEL 14222 Q-3-A35.07.07
'Q ~-A35.02.01 Mr. K. V. Seyfrit, Director, Region IV U. S. Nuclear Regulatory Commission Office of Inspection & Enforcement 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76012
SUBJECT:
Waterford SES Unit No. 3 Docket No. 50-382 Final Report Status for Significant Construction Deficiency No. 7 Loose Control Element Drive Mechanism Guide Cones
REFERENCE:
LPL Letter 9582 to NRC dated September 12,1978 (Interim Report)
LPL Letter 11905 to NRC dated August 31, 1979 LPL Letter 12778 to NRC dated December 28, 1979
Dear Mr. Seyfrit:
In accordance with the requirements of 10CFR50.55(e), we are hereby providing two copies of the Final Report of Significant Construction Deficiency No. 7,
" Loose Control Element Drive Mechanism Guide Cones".
Yours very truly, D. L. Aswell DLA/LLB/ned cc:
- 1) Director Office of Inspection & Enforcement U. S. Nuclear Regulatory Commission Washington, D. C. 20555 (with 15 copies of report) cc:
) Director Office of Management Information and Program Control
/7 U. S. Nuclear Regulatory Commission Washington, D. C. 20555 S
(with I copy of report)
I j
(
8006180 38 p