ML19317G635
| ML19317G635 | |
| Person / Time | |
|---|---|
| Site: | Rancho Seco |
| Issue date: | 10/11/1972 |
| From: | Deyoung R US ATOMIC ENERGY COMMISSION (AEC) |
| To: | Mallay J BABCOCK & WILCOX CO. |
| Shared Package | |
| ML19317G634 | List: |
| References | |
| NUDOCS 8003240918 | |
| Download: ML19317G635 (1) | |
Text
4 O
G'.
j+
/
e, UNITED STATES ATOMIC ENERGY COMMISSION j.")
W ASHINGTON. D.C. 20$45
,%; \\ r 5
ua, e,,
n 007 11 W2 Mr. James F. Mallay Manager, Licensing Babcock & Wilcox P. O. Box 1260 Lynchburg, Virginia 24505
Dear Mr. Mallay:
The regulatory staff has completed its review of Babcock & Wilcox Topical Report BAW-10013, dated December 1971, and entitled " Study of Intergranular Separations in Low Alloy Steel Heat-Affected Zones Under Austenitic Stainless Steel Weld Cladding" with revised pages 2-1, 2-2, 2-3, 5-3 and 5-4 dated February 15, 1972. A summary of our review is enclosed for your information.
As a result of our review we have concluded that Topical Report BAW-10013 as revised February 15, 1972, will be acceptable by reference in applications for construction permits and operating licenses.
Sincerely,
, Lif,lf....
/
.y
'r R. C. DeYo[, Assistant Director for Pressurized Water Reactors Directorate of Licensing
Enclosure:
Topical Report Evaluation 8 003 240 f/7 4