4 1
~
00MI1I.7,',w v.
SiMUD
~
~," W i
SACRAMENTO MUNICIPAL UTILITY DISTRICT C 1708 59th Street Box 15830, Sacramerito. California 95813;(916)452 3211 July 15, 1975 4
s
[ ' g Y,s
\\
Director
?
Division of Reactor Licensing vul221975
- U. S. Nuclear Regulatory Commission
- 83. w't tum d
Washington, D. C.
20545 TQ
't
-Q Re: Operating License DPR-54 I p\\
Docket No. 50-312 Unusual Event 75-6
Dear Sir:
As defined by Technical Specifications " Appendix B",
Section 2.6.2.C, we are reporting the following Unusual Event as UE 75-6.
On May 5, May 16, May 23, and May 26, it has been noted that the conductivity of the effluent waste water exceeded that
\\
associated with a total dissolved solids level of 850 mg/1, the d
limit set in Technical Specifications " Appendix B", Section 2.3.A.
e These events were very brief spikes which appeared as the controlled dU.ution for a retention basin release was being established. On May 27 the limit was again exceeded; however, on this occasion the dissolved solids level remained at approximately 1600 mg/l for fifteen minutes, and no retention basin release was noted.
It has been found that the conductivity sensing system
~
overreacts somewhat to conductivity changes, and upon releasing the retention basin and adjusting the dilution flow the meter records a spike. To correct this the system will be desensitized, so as not to record an invalid high conductivity level. There is nc apparent reason for the 15-minute indication. Records show no release which would give such a reading at that time, the instrumentation has been checked and is operating properly, and no calibration checks were being performed en the instrument at that time.
/,. C %129,c $
[.>-
/
There was no plant transient associated with this event.
~'
.N
,/ } ' g, Respectfully.
F 5h5
\\
\\
. Mattimoe
'D ~
... 4
/N Assistant General Manager
['1 (y) s %..
and Chief Engineer
.)
cc: R. H. Engelken, Region V
[
SWY BDIT REGION-m AN ELECTRIC SYSTEM SERVING MORE THAM 600.000 IN.THE HEART OF CALIFORNIA