ML19317D090

From kanterella
Jump to navigation Jump to search
Transmittal of the Final After Action Report of the Diablo Canyon Power Plant MS-1 Exercise Conducted on August 7, 2019
ML19317D090
Person / Time
Site: Diablo Canyon  Pacific Gas & Electric icon.png
Issue date: 11/13/2019
From: Fenton R
US Dept of Homeland Security, Region IX
To: Scott(Ois) Morris
Office of Nuclear Reactor Regulation, NRC Region 4
Shared Package
ML19317D405 List:
References
Download: ML19317D090 (2)


Text

, - Scott A. Morris Regional Administrator U.S. Nuclear Regulatory Commission

_ -Region IV-Office_

1600 East Lamar Boulevard Arlington, TX. 76011-4511

Dear Mr. Morris:

p.s. Department of Homeland Security Region IX 1111 Broadway, Suite 1200 Oakland, CA 94607-4052 The Dep~ent of Homeland Security's Federal Emergency Managen;ient Agency (FEMA) Region IX Technological,Haz.ards Branch evaluated a Medical Services (MS~l) exercise on August 07, 2019. Enclosed is a copy of the final After Action Report (AAR) of the Diablo Canyon Power Plant (DCPP) MS-1 exercise, conducted in the.County of San Luis Obispo, Califorpia l

The purpose -of the MS-1 exercise was to assess the level of local* preparedness in responding-to a radiological event-occurring at or within the' vicinjty of the pCPP emergency planning zone. The final AAR was prepared in coordination with the DCPP Offsite Response Organizations (ORO).

No Level 1 or Level 2 Findings were identified during the M~-1 exercise.

Based on FEMA's evaluation of demonstrated criteria for the August 07, 2019, MS-1 exercise,the capabilities*.ofthe affected OROs are adequate to provide continued reasonable assurance.

Reasonable assurance is defined in the Code of Federal Regulations,Title 44 § 350.5(b) as "assurance that appropriate_ measures can be taken off site in the event of a radiole>gical emergency".

If you have.any questions or need additio~ information, please contact Johanna Johnson, Regional Assistance Committee Chair, at (510) 627-7164 or Johanna.Johnson@femadhs.gov; or Alberto Sifuentes, DCPP Site-Specialist, at (510) 627-7108 or Albe~o.Sifuentes@fomadhs.gov.

_www.fema gov -

Mr.. Scott A. Morris Page2 Enclosure cc:

Sincerely, Robert J. Fenton Regional Administrator FEMA Region IX U.S: Nuclear Regulatory Commission, Document Control Desk One White Flint North, 11555 Rockville Pike Rockville, MD 20852 Vanessa Quinn,. REP Branch Chief -

Federal Emergency Management Agency, Technological Hazard Division:, HQ 400 C. St, S. W.