Text
_
Geyg'a Pow Comca y 2M Peacruee Sneer P's! C" ce acu 4545 4 wa Gecrg.a 30302 5 eprcre C4 522-6C60 L
GeorgiaPower W, A. Widner
!,ll,."alG',.]*nG' " ' " * **'
tre murrem eectre system May 20, 1980 U. S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Washington, D. C.
20555 NRC DOCKETS 50-321, 50-366 OPERATING LICENSES DPR-57, NPF-5 EDWIN I. HATCH NUCLEAR PLANT UNITS 1, 2 PROPOSED NPDES PERMIT REVISION Gentlemen:
The Plant Hatch Environmental Technical Specifications (Appendix B to the Operating License) require in section 5.7.3.2 that the NRC be notified of proposed revisions to the NPDES permit. The attached letter to the Georgia Environmental Protection Division dated April 29, 1980, provides justification of the proposed change.
Yours very truly, W h. Y I
W. A. Widner Vice President and General Manager Nuclear Generation RDB/mb Attachment xc: Ruble A. Thomas George F. Trowbridge, Esquire R. F. Rogers, III n(
[
soosero g43
j
/
Georgia Power Company 230 Peachtru Stre:t
(
(
)
1 Post Off.co Bo 4545
(
i Atlanta. Georgia 3Ql03 Telephone 404 522 6003 L
Power Supply Engineering and Services tre saws eu trc wir April 29, 1980 P
T HATCH LRPDES Permit No. CA OC04120 Mr. Gene B. Welsh, Chief Water Protection Branch Environmental Protection Division 270 Washington Street, S.W.
Atlanta, Ga.
30334
Dear Mr. Welsh:
Part III, paragraph 7 of the subject pernit states that if after si.t months of monitoring, a discharge is shown to consistently meet the effluent limits established in the permit, the permittee may request I
a reduction in the frequency or the elimination of the monitoring re-quirements for that discharge. Based on this permit provision, we are requesting that the monitoring requirements established for our dis '
charge 001A2 - Low Volume Waste (Pressure Filter Backwash) at Plant Hatch be eliminated.
Attached are the r sults of analyses performed on this discharge covering the last 15 months. As can be seen from these resulte, the discharge has consistently been well within the established limitations and, therefore, meet the criteria for elimination of the monitoring requirements.
Should you have any questions or comments, please advise.
Sincerely, T. E. Byerley Manager of Environmental Affairs CNH/jh Attachment be:
(All W/0 Attachments)
J. H. Boykin J. R. Jordan O. C. Rittenhouse W. A. Widner R. H. Bohler
('
(
s, O'.'.Y;T!*2L's' OPSMTTN MON!TORING Re. PORT
~
I or.4' i Po e Cetan. ore From: 01-01-79 m-h w~
n To: 03-31-79 P.O.
3 m 4545 Atlanta, Geor;ta 30309 Dermit Number:
0004120 i
Discharic Loca: ion:
001A
- Low Volume Waste '(pressure filter backwash) i Tvou o:? Sa:.nle :
Grab FrecuencV of Analvki.5:
2/mo.
Parameter:
Suspended Solids Oil & Grease off m2/1 me/l pH Units Limics:
Avg.
30 Avg.
15 Min. 6.0 Mcy.,
100 Ma:<.
20 Ma:<. 9.0 Location Dato I
Filter A 01-08-79 0.9
<5 7.8 Filter B 01-08-79 1.9
<5 7.8 Filter C 01-08-79 1.3
<5 7.8 Filter D 01-08-79 1.5
<5 7.8 Filter A 01-17-79 2.4
<5 7.3 Filter B 01-17-79 2.7
<5 7.9 P.ter C 01-17-79 3.4'
<5 7.9 1_tter D 01-17-79 2.7
<S 7.9 Filter A 02-06-79 1.2
<5 7.6 Filter B 02-06-79 8.1
<5 7.6 Filter C 02-06-79 2.8
<5 7.6
~
Filter D 02-06-79 2.8
<5 7.6 Filter A 02-19-79 1.4
<5 7.6 Filtor B 02-19-79 0.4
<5 7.6 Filter C 02-19-79 0.3
<5 7.6 Filter D 02-19-79 2.8
<5 7.6 Filter A 03-05-79 0.3
<5 7.8
. Filter 3 03-05-79 0.3
<S 7.8 I
Filter C 03-05-79 0.3
<5 7.8 i
Filter D 03-05-79 O.7
<5 7.8 Filter A 03-19-79
.l.8
<5 7.8 i
Filter 3 03-19-79 3.6
<5 7.8 Filter C 03-19~79 2.8
<5 7.8 Filtcr D 03-19-79 3.5
'<5 7.8
!! umber of Samplos:
24 24 24 Averaco value:
2.1
<5 Maximun Value:
8.1
<5 7.9 L.imum Value:
0.3
<5
. 7.6 L'imits Er.cceded:
0 0
0 9
6e e se gee.
g a.
,,gg
,,a
QUARTERLh.PERATIONMONITORINGREPOR.
(.
e Georgia Power Company Plant Itacch From: 4-01-79 O.
Box 4545 To: 6-30-79
)
anta, Georgia 30302 Permit Number:
0004120 Discharge Location:
001A 2 Low Volume Waste (pressure filter backwash)
Type of Sample:
Grab Frequency of Analysis:
2/mo.
Parameter:
Suspended Solids Oil & Grease pH mg/l me/l pH Units Limit's :
Avg.
30 Avg.
15 Min. 6.0 i
Max.
'100 Max.
20 Max. 9.0 Location Date Filter A 04-02-79 3.2
<5 8
Filter B 04-02-79 4.0
<5 Filter C 04-02-79 4.1
'5 Filter D 04-02-79 4.6
<5 Filter A 04-16-79 0.3
<5 Filter B 04-16-79 0.2
<5 Filter C 04-16-79 1.6
<5 Filter D 04-16-79 0.2
<5 i
f] F.iiter A 05-07-79 2.5
<5 i
Filter B 05-07-79 5.9
<5 i
4
- Filter C 05-07-79 1.0
<5 i
Filter D 05 07-79 2.3
<5 I
Filter A 05-25-79 4.0
<5 Filter B 05-25-79 2.0
<5 Filter C 05-25-79
- 4. 3
<5 Filter D 05-25-79 2.4
<5 g
Filter A 06-05-79 0.9
<5 Filter D 06-05-79 5.0
<5 I'
Filter C 06-05-79 2.3
<5 l
Filter D 06-05-79 2.1
<5 8
?ilter A 06-18-79 2.4
<5 Filter B 06-18-79 5.1
<5 Filter C 06-18-79 4.4
<5 l
?ilter D 06-13-79 3.5
<5
(
' umber of Samples :
24 24
\\verage Value:
2.8
<5 faximum Value:
5.9
<5 linimum Value:
0.2
.ir :s Exceeded :
<5 0
0
(
- ote: 3) pil-is reported at Combined Plant Waste (001E and 001E )-
i 2
3 t
...-.-.r......-.--...-
1
l!
l
?
(
(
- 2 of:7 1
QUARTERLY OPERATION MONITORING REPORT eorgia Power Company From: 07-01-79 i lant Hatch To: 09-30-79
.O.
Box 4545 tlanta, Georgia 30302 Permit Number:
0004120 t
Discharge Location:
001A, - Low Volume Waste (pressure filter backwash) e Type of Sample:
Grab
- requency of Analysis
2/mo.
arameter:
Suspended Solids Oil & Grease mg/l me/1
- imits
Avg.
30 Avg.
15 Max.
100 Max.
20
'ocation Date t
'ilter A
' 07-02-79 3.0
<5 i *ilter B 07-02-79 4.1
<5 i 'ilter C 07-02-79 2.4
<5 l'ilter D 07-02-79 2.0
<5 1'i(terB
'i
.r A 07-17-79 3.9
<5 l
07 17-79 7.8
<5 1'ilter C 0: 17-79 0.9
<5
'ilter D 07-17.79 3.9
<5
'ilter A 08-07-79 1.2
<5 ilter B 08-07-79 2.2 7
'ilter C 08-07-79 2.2 6
' ilter D 08-07-79 0.6
<5 ilter A 08-20-79 0.3
<5
< ilter B 08-20-79 2.3 5
1'ilter C 08-20-79 1.1
<5
'ilter D 08-20-79 0.7
<5 11ter A 09-04-79 0.8
<5
. ilter B 09-04-79 0.4
<5
- ilter C 09-04-79 3.6
<5 ilter D 09-04-79 0.6
<5 ilter A 09-19-79 1.8
<5 ilter B 09-19-79 0.4
<5 i ilter C 09-19-79 1.2
<5 liter D 09.19-79 0.81
<5
- 'W. r of Samples
6 6
vebage Value:
2.0 5
1ximum Value:
7.8 7
,inimu= Value:
0.3
<5 imits Exceeded:
0 0
j
Pig #2bs3
(
I I
QtfARTElti.Y Ol'ERATIOtf MOff1TORIllG REPORT Gs gia Power Compatiy From: 10-01-79 Plant llatch To: 12-31-79 P.O.
Box 4545 Atlanta, Georgia 30302 Permit tiumber:
0004120 Discharge Location:
- 001A, Low Volume Waste (pressure filter backwash)
Type of Sample:
Grab
' Frequency of Analysis:
2/mo.
) Parameter:
Suspen.id Solids Oil & Grease q,
.:. /1 ms:/1
. Limits:
Evg.
30
- Avg.
15 Max.
100 Max.
20 I
i t.ocation Date
' Filter A 10-01-79 2.6 8
B 2.0 7
i C
1.8
<5 D
2.1 7
?ilter A 10-15-79 2.3
<5
(
B 0.3
<5 C
2.6 5
D 0.3
<5
' Tilter A 11-05-79 1.2
<5 B
2.6
<5 C
3.7
<5 D
2.4
<5
' 'ilter A 11-19-79 1.4
<5 B
2.1
<5 C
3.9
<5 D
2.0
<5 ilter A 12-03-79 0.9
<5 B
2.3
<5 C
l.7
<5 D
1.5
<5
'ilter A 12-17-79 0.6
<5 B
0.9
<5 C
0.8
<5 D
2.9
<5
' umber of Samples:
24 24
.ve 1ge Value:
1.9 5
. ak.aum Value :
.3 4 8
inimum Value:
C 'J
<5 ih:it.s Exceeded:
0 0
. ~ -........
- Page 2 of 8
(~
~
{
QUARTERLY OPERATION MONITORING REPORT Georgia Power Company From: 01-01-80 Plant Hatch To: 03-31-80 P.O. Box 4545 Atlanta, Georgia 30302 Permit Number:
0004120 Low Volume Waste (pressure filter backwash) j Discharge Location:
001A 2
Type of Sample:
Grab Frcquency of Analysis:
2/mo.
Parameter:
Suspended Solids Oil & Grease mg/l mg/l Limits:
Avg.
30 Avg.
15 Max.
100 Max.
20 Location Date Filter A 01-07-80 0.1
<5 Filter B 01-07-80 0.0
<5 Filter C 01-07-80 0.0
<5 Filter D 01-07-80 0.0
<5 Filter A 01-21-80 0.1
<5 Filter B 01-21-80 0.4
<5 Filter C 01-21-80 0.7
<5 Filter D 01-21-80 0.4
<5 Filter A 02-05-80 2.6
<5 Filter B 02-05-80 1.7
<5 Filter C 02-05-80 3.4
<5 Filter D 02-05-80 19
<5 Filter A 02-18-80 5.6 8
Filter B 02-18-80 4.0 7
Filter C 02-18-80 2.0 6
Filter D 02-18-80 1.6
<5 Filter A 03-03-80 0.4
<5 Filter B 03-03-80 0.4
<5 Filter C 03-03-80 0.3
<5 Filter D 03-03-80 0.1
<5 Filter A 03-17-80 2.0 5
Filter B 03-17-80 3.5 5
Filter C 03-17-80 2.0
<5 Filter D 03-17-80 1.4 9'
Number of Samples:
24 24 Average Value:
1.4 5
Maximum. Value :
5.6-9
~
Minimum Value:
0.0
<5 Limits Exceeded:
0 0
- $.