LER 78-008/03L-0:on 780315,valve 1FDW-108 Failed to Close. Failure Has Occurred Previously.Caused by Apparent Inability to Withstand Environ.Valves FDW-106 & 108 Will Be Replaced W/Valves of Appropriate Design
ML19316A384
Person / Time
Site: Oconee Duke Energy icon.png
Issue date: 04/11/1978
From: Ken Wilson
DUKE POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
Shared Package
ML19316A379 List:
References
LER-78-008-03L, LER-78-8-3L, NUDOCS 7912110645
Download: ML19316A384 (1)


Text

. - ____.

O

.gr==ses u.s.uuctemecutarna co.uission LICENSEE EVENT REPORT EXHIBIT A cournot stoex: l l l l l l l@ teteAss ramr on tves ALL r.souinto iNFCRMAnoN) i .

Io I 8i 9I l SWCEN144 7

P l NCC04 f lE l 1 l@15010 l- l 0 l 0l0 l010 l -l0 l 30 l@

le wCIN54 NyM.6A a$ 4l1 WC&M&4 ry,gl1A l ll 1l@

l

$7 CA r b, lg cowr

  • [y'*$ lL ao l@l 0 l 5 l 0l 0l0 l 2 l 61 9@l =

013 11 l 5 l 718a@l 0 l 4 l1 11 l 7 l8 l@

.i coc=aruuu.an = aviar omre a aercaroara so l I

Io t 2I lEveur At 0830, cascairnon after a sample Ano was racenste taken ccNssouescase 1B OTSG, 1FDW-108 @ from th failed to i {

ITTT1I close. The redundant isolation valve 1FDW-107 operated properly main- i l 1

g[ taining containment integrity. Since containment integrity was not ,

i io t si l jeopardized, the health and safety of the public were not endangered. ,

' o is l l  ;

[o lil l g

10idj l 1

> . . l

.o l

'ce'u" Ts! MM. c= co.,a==o. c su, "

ja}9l I 8 l H l J l @ {@ l B l @ lV ( A l L l V l E l X lg lf;l,g ,=" ,g 9 to ii 12 13 18 19 ;Q 6 IV emf TEAR A Ar NQ. Oct ry y=

e,a'84f40 1718 I u u l-l u

1010181 1-l 10 l 3 l lL l g q

l(il u a u :n a u u u E=N "*Sc"E cEIt' E "E= ouas 'E!O'r"rE' po'l".SO.. "d" ***" "'"'

L e e Li i e Lz i s cAuss esseniencN ANo cOaRECOVE AcDON3 @

se ,i, oi oi o i se g is g'?7is L9,TY3.,e i li to 1 l The initial corrective action was lubrication and cycling of valve. ,

g; Failure of this type has occurred on several occasions, evidently gl indicating that this valve simply cannot withstand the necessary ,

Ii,3i [ environment. Therefore, the valves (FDW-106 and -108) uill be replaced  ;

i i i .1 I in the future with valves of anorooriate design.

> e s  ;

480*EM . QT1*tM sTATV3 as my 033COV E3CMirTI NA i

  • i s 1 [E_J@ l ll 0l 0'sl@l l l B gl Observation cuEng roue"uwsampling, 8.jny,r, co'j r.,r is 4 *e = ,,

aitaAss II' Is I W @o en astiass(,_Z,J@l ou NA ,o,.criviry @ l l Nn,r,,,,,,,,,,,,g 9c

' nasc=='e*t n,esO s '*

  • l so wwween rm essen me= @

R

' l '0101 '

Ol@l Zl@l '*

NA l

n ase== e't'iaudlu no

.u ...

encaime @

li_LaJ 7 8 9 l oI of oI@l 2 ii NA l

'/d's * * "

I'i I il 1 @ Il ,*'c".',**o',,'" " @ NA

' ' ' g

~.u '*r.

.uuro enemme= @ sac use ent.v 12 t al L!U61 NA

  • a s o i i iriiri,ii,ir 1

,, ,, ,, )

nauscammeranen K. R. Wilson (704)373-8197 twene:

)