TN Metropolitan Edison Co' pany m
Post Office Box 480 g
Middletown, Pennsylvania 17057 717 9444041 Writer's Direct Dial Number May 20, 1980 TLL 233 Office of Inspection and Enforcement Attn:
B. H. Grier, Director U. S. Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, Pa.
19406
Dear Sir:
Three Mile Island Nuclear Station, Unit I (TMI-1)
Operating License No. DPR-50 Docket No. 50-289 IE Bulletin 80-04 In our response to Bulletin 80-04 of May 9, 1980 (TLL 228), we stated that the TMI-I containment design pressure was 60 psig.
In fact, the containment design pressure for TMI-I is 55 psig.
However, the statements made in our initial response are accurate when assuming the 55 psig design pressure.
Therefore, no further revision to our previous submittal is necessary.
Sincerely, e
V J. G. Herbein Vice President TMI-I JGH:DGM: hah cc: Office of Inspection and Enforcement Division of Reactor Operations Inspection Washington, D.C.
20555 J. T. Collins B. J. Snyder 80 0600 DN 7 Q Metrocottan Ecson Company is a Memcer of the General Pubhc Utdities System