. _ _. _.
ry*,
b n D @g Distribution:
Docket File O
M Project File k
9 NMSS R/F pg;3 o o en FCAF R/F LCRouse
~ ~ ~ ~
WBurkhardt JEAyer Decket No. 70-8 JShafer N3
.Th0 rat:DUM FOR: Leland C. Rouse, Chief Advanced Ftrel and Spent Fuel Licensing Branch FROM:
J. E. Ayer/U. Burkhardt Advanced Fuel and Spent Fuel Licensing 3 ranch SU3 JECT:
REVIEW 0F SEVERE WEATFER "ETEOROLOGY AT CATTELLE NEPCRIAL IfISTITL'TE, COLUMEUS OHIO The subject r= pert prepared by Professor T. T. Fujita, University of ChicG o, is attached. The purpose of this memorandum is to recocraend acceptance of the attached review as a basis for succeeding increments of the analysis of the effet ts of natural phenocena upcn existina, plutenium facrication facilities. A draft of the sucject report has been sent to fcur mteorologists for review and coc: cent:.
Or, 2. F. ftbey, MRC; J. E.
Carson, Argonne National Laboratory (A: L); F. Kornegay, N'L; and D. . Pepper, Savannah P.iver Laboratory (SRm); as well as Texas Tech. Stmetural Engineers, and W. E. Vesely, J.E. Ayer, and N. Burkhardt,f;RC. A have contacted all reviewers by telephone and they have reviewed the report and have no substantive cement contradictory to the author's study cr conclusions.
'.-!e recccmend that this review including its summary and conclusions be adopted as a staff position subject to your approval. Subsequent to your approval we will make copies available to the public and to Sattelle Memorial Institute in accordance with review and documentation procedures agreed upon and described in our February 10, 1977 memoranduct to R. M. Bernero.
S J.E. Ayer Advanced Fuel and Spent Fuel Licensing Branch
(
W. Burkhardt
- g. p..g 4 Advanced Fuel and Spent Fuel Licensing Branch Approved by Lelano C. Rouse, Chief Advanced Fuel and Spent Fuel Licensing Branch Division of Fuel Cycle and Material Safety 4
gy
Enclosure:
As <taeed 4
omes >
pr i
FrA _
FCA M
[r; M
JEAyer: fib i WBurkh6Ydt LCRd'use suanaus
.3_ 2K
, />8 m, oars i.c %ma.m sscuome
~'r
~
.