PRituRY AUX. OPERATORS LOG-LUDS PANEL SH II of 3 LOG DAILY (SHIFT FOREMAN REVIEW) -
AND RETURN TO OPS ENGINEER 3 M P -7 9 DATE
[
11-7~~ j _ 7-3_ _
( YJ T 1
~_
RADWASTE DISPOSAL PANEL T~
LUDS PANEL (DATE, TIME & INK CHARTS; TEST ALARMS)
(/)
[
,ff////////77f/7//
RB SUMP-EILIER STATUS (ll-7 CIRCLE IftSERVICE; X EXHAUSTED UNITS)
\\MDL-F-80)
WDL-F-8B BYPASSED MWST (WDL-T-2) LEVEL (0-9')
(FT) 7'
- 7. -l _ [Y MISC. RW FLOW INTEGRATOR (02400 RECORD &RESETL(/)
_DI O l C / l 7 L3 GALS AUp $ttMPMfLTER STATUS (11-7 CIRCLE IflSERVICE; X EXHAUSTED UNITS)
~
_(WDL-F-3A )
WDL-F-3B BYPASSED CONTAM. DR. RM. SUMP LEVEL (6-19")
(FT) s 7I 1A RB SPRAY RM SUMP LEVEL (12-25")
(FT) 13 1B RB SPRAY RM SUMP LEVEL (12-25")
(FT)
/d
'i AUX. BLDG. SUMP LEVEL (12-32")
(FT)
~S RX. BLDG SUMP LEVEL (12-25")
(FT)
- f. T.
lA DH REMOVAL SUMP LEVEL (12-25")
(FT)
IB DH REMOVAL SUMP LEVEL (12-25")
(FT)
(
NEUT. TANK (WDL-T-8A) LEVEL (0-12')
(FT)
/C
/o #
/0._5 flEUT. TAMK (WDL-T-8B) LEVEL (0-12')
(FT)
/og_
/ o. 2
/C. 2.
NEUT. TANK FILTER STATUS (11-7 CIRCLE INSERVICE;X EXHAUSTED UNITS)
WDL-F-4A WDL-F-4B A//8 AUX. BLDG. SUMP TK. (WDL-T-5) LEVEL (0-4.33') (FT) 1 6~
3I U
CONTAM. DR. TK. (WDL-T-llA) LEVEL (0-4.5')
(FT) f
/"
/
r/ V CONTAM. DR. TK. (WDL-T-llB) LEVEL (0-4.5')
(FT)
L.
/
/
CONTAM. DR. TK. FILTER STATUS (11-7 CIRCLE INSERVICE; X EXHAUSTED Uf(IT)S WDL-F-7A WDL-F-78 BYPASSED N/J (1-13')
O(F N'
7 I5 RCBT "A" (WDL-T-1A) LEVEL (WDL-T-1A) TEMP.
(MAX.150)(f))
F PO
'////////- '///M Wl//Y////$f/
RCBT "B" (WDL-r-1B) LEVEL (1.3') g (
/0 (MAX.150)(gT)
/o
</. s (WDL-T-18) TEMP.
F) 57-f
'/////////////,
RCBT C (WDL-T-1C) LEVEL (1-13')
(FT) ff
- g. r e7 (WDL-T-1C) TEMP.
(MAX.150) (4 )
Pf'
'/////////////
DEB 0 RATING DEMIN. D/P (Kl A/KlB)
(MAX. 20) (PSID) a//0
'///////////d CLEANUP DEMIN. D/P (K2A/K28)
(MAX. 15) (PSID)
N
/////////////
CLEANUP DEMIN. & FILTER STATUS (11-7 CIRCLE INSERVICE; X EXHAUSTED UNIT,S)
WDL-F6A WDL-F6B WDL-K2A WDL-K2B WDL-F9A WDL-F9B N8 M5 EVAP. COND. DEMIN. D/P (K3A/K3B)
(MAX. 15) (PSID) l
/t/6 V##///#/W#///,
'EVAP. COND. DEMIN. STATUS (11-7 CIRCLE MODE OF OPERATION & LEA 0 UNI _TJ PARALLEL SERIES LEAD A OR B BYPASSED A OR S
/l//f ML5 E.C.T.T. (WDL-T-9A) LEVEL (0-14')
(FT) eY E.C.T.T. (WDL-T-98) LEVEL (0-14')
(FT) 3 v
6./
TOTAL DISCH. INTEGRATOR (02400 RECORD & RESET)
(/)
Ol O
'A /lClf GALS CONC. WASTE TK. (WDS-T-2) LEVEL (2-10')
(gT)
O
/M O
(WDS-T-2) TEMP.
(
)
( F)
PO 0
- 0 RECLAIMED B. A. TK. (WDS-T-3) LEVEL (2-10')
(
F, f D
8 'I (WDS-T-3) TEMP.
(150-160) ({T)
F)
/30
!3D
/.3 0 SPENT RESIN ST. TK. (WDS-T-1A) LEVEL (0-12.5') (FT)
(9 T//////////////-
(UDS-T-1B) LEVEL (0-12.5') (FT) 80 01170 57#g/
7///,/,/g/
g
/'///jj/
LMMMARY AUX OPERATORS LOG-LUDS PANEL 1 SHEEl 2 of 3 LOG DAILY (SHIFT FOREMAfl REVIEW) -
AtlD RETURN TO OPS EllGINEER
~;
s, DAlC WASTE GAS VEtlT. HDR. PRESSURE A-L0 2.5-5) 5
{A-HI2.5-8)(gSIG)
WDG COMPRESSOR SEAL WATER TEMPS (MAX.
)
( l')
LI-26 f.Y s
WDG COMPRESSOR STATUS A l-7 CIRCLE STATUS)
M g/#f##fgJ7
~
RUN(OFD (AUTO-LO WDG-P-1A RUN OFF AUT0-LO) AUT0-Ill WDG-P-18 AUT0-HI WDGDECAYTANK(WDG-T'1A)" LEVEL
' ((0-1100)
(PSIG)
O O
~~O PRESSURE (WDG-T-1A) 12-18")
(FT)
,. f3
,3 J
WDG DECAY TANK (WDG-T-18) PRESSURE (0-110)
(PSIG) f(
/0 fo (UDG-T-1B) LEVEL
-(12-18")
(FT)
C) o
.o STATION GAS DISCH. INTEGRATOR (02400 RECORD & RESET)
(/)
pos-r co 7//,//
/ // /
i-
/ //f7 i </
HAYS GAS ANALYZER PANEL
/
l TEST TLARMS, REPLACE BULBS
(/)
i c-Weg/44,9k OXYkri CONC. (VENT HDR.)
(MAX'3%)
(%)
///g/7AWZf
'//
HYDR 0GEil CONC. (VEilT HDR.)
(MAX. 3%)
(%)
o
,r,7,f @g7,7M 0 SAMPIE FLOW (NO WATER)
(
)
(SCFM) 3a 3e
./ >
H,2, SAMPLE FLOW (N0 WATER)
(
)
(SCFM) 33-R 3a AUTO SCANNER STATUS-CIRCLE POINi5 IN SCAN I
4 3
4 b
(11-7) 6
[7) 8 9'
10
' GAS PUMP (Sil-P-1) RUNNING & Pl-200/
(0-2 PSIG)
(/0K) l g - -l g.-
lV CHEMICAL ADDITION PANEL TEST ALARMS, REPLACE BULBS
(/)
V
//,/,/,rf,/,-y,r,/f B.A. MIX TANK (CA-T-1) LEVEL
(
)
(CA-T-1) TEMP.
(
)
(gT)
(
// p gr
// 5 "
F)
/j F f yy fy( '
RC EVAPORATOR CONTROL PANEL ONLY WHEtt IN OPERATION DISTILLATE CONDUCTIVITY
[0-6UMHO)
(UMHO)
/)j /S DISTILLATE FLOW
,a f
,;J (MAX.15)
(6PM)
J F'>
A~
DISTILLATE TOTALIZER (02400 RECORD) l fl lf l GALS ~~
CONC. VACUUM (19-20.)
("VAC) f f
GAS STRIPPER VACUUM (18-20T
("VAC)
FEED TANK PRESSURE (2.5-5)
(PSIG)
)
i LEVEL (22-26)
("
)
CONCEtlTRATOR LEVEL (18-22)
('
)
REBOILER STEAM PRESSURE
(
ofg0NC)(PSIG) l j
PREHEATER STEAM PRESSURE (il/2"H g
ADJ. FOR 40 PREHTR)(PSIG) f ST
////N /.//// Mj////////y~i CONC. STEAM PRESSURE
(**)
(PSIG) l CONCENTRATES FL0ji(WHEN DISCH.)
(
)
(
{
{
FEED TAilK TEMPERATURE (Mill.160)
(gPM)
F)
SYSTEM TEMPERATURES
~
1 CONC. B0ILER SECTION TEMP.
- (160-165)
(O )
F 2.COND. CLG. WATER INLET TEMP.
(70-90)
( F) 3.COND. CLG. WATER OUTLET TEMP.
(120-140)
( F) i
- 4. Gas stripper prehtr inlet. temp (150-160)
( F)
- 5. GAS STRIPPER PREHTR OUTLET TEMP.
(190-200)
{ F)
- 6. GAS STRIPPER REBOILER CilAMBER TEMP.
(165-170)
( F)
- 7. Gas STRIPPER COND. CLG. INLET TEMP (70-90)
( F)
- 8. GAS STRIPPER COND. CLG. OUTLET TEMP (95-115)
( F)
~/
- 9. DISTILLATE EFFLUENT TEMP.
(85-120)
( F) t/
(//
ni y
\\L)
PRIMARY AUX. OPERATORS LOG-LWOS pat 1El.
i SHEET 3 of 3 LOG DAILY (S!!IFT FOREMAN REVIEW) -
i AND RETURN TO OPS EtlGINEER 3
D.%TE l.
11-7 L 7-3 f 3-li RC EVAPORATOR PUMP STATUS (11-7 CIRCLE INSERVICE UNITS)
~ ~ ~ '
u FEED DIST.
CONC. VAC.O G.S VAC, G.S PUMP PUMP PUMP PUMP PUMP A-B A-B A-B A-B A-B
/1//$
g>( 5 N/5 et I
T e
e e
S e
o e
e e
e e
e e
e e
DATE
,,4.-
OPERATI0tlAL FUI!CTI0ilS DATA SilEET_
List All floteworthy Functions As Performed During Shift.
2300-0700 1,
2.
3.
4.
5.
6.
7.
0700-1500 1.
2.
3.
4.
5.
6.
7.
1500-2300 1.
2.
3.
4.
5.
6.
7.
- n 11r2 /,
//
7-3 3-11 AllX. OPERATOR SIGilATURE ////['
- f../I[ L,,crA _,
'h'/Oawn SitifT FORLMAli SIGilAfuRE 3,g
[
yy g,4.g/ j p fg],
C 2
_.__._