ML19310A691

From kanterella
Jump to navigation Jump to search
Notification of 800624-26 Meeting W/Util in Clinton,Il to Discuss Forthcoming Caseload Forecast Panel Visit
ML19310A691
Person / Time
Site: Clinton 
Issue date: 06/09/1980
From: Buckley B
Office of Nuclear Reactor Regulation
To: Schwencer A
Office of Nuclear Reactor Regulation
References
NUDOCS 8006230028
Download: ML19310A691 (4)


Text

- _ _ _ - _ _ _ _ _ _

.te.

n nro v

UNITED STATES

,f o,j NUCLEAR REGULATORY COMMISSION 5

j WASHINGTON D. C. 20555 JUN 9 1980 Docket No. 50-461 MEMORANDUM FOR:

A. Schwencer, Acting Chief, Licensing Branch No. 3, Division of Licensing FROM:

.Bart Buckley, Project Manager, Licensing Branch No. 3, Division of Licensing

SUBJECT:

FORTHCOMING CASELCAD FORECAST PANEL SITE VISIT TO CLINTON POWER STATION, UNIT 1 DATE & TIME:

Tuesday-Thursday, June 24-26, 1980 - 9:00 a.m.

LOCATION:

Clinton Unit 1 Site Clinton, Illinois PURPOSE:

The NRC Caseload Forecast Panel (B. Buckley, H. Livermore, W. Lovelace, H. Wescott) will visit the Clinton, Unit 1 site to determine the status of completion of construction in regard to Clinton Unit 1. Specific items to be discussed are delineated in the enclosed agenda.

PARTICIPANTS:

NRC - STAFF (B. Buckley, H. Livermore, W. Lovelace, H. Wescott)

ILLIN0IS POWER COMPANY (G. Wuller, et al) m cr,

lh I d uc.ht p;

Bart Buckley I

Licensing Branch No. 3 Division of Licensing

Enclosure:

Agenda ces w/ enclosure:

See next page 800628001$

Mr. L. J. Koch, Vice President Illinof s Power. Company

- 500 South 27th Street Decatur,. Illinois 62325 cc: Mr. Peter V. Fazio, Jr.

~Schiff, Hardin & Waite 7200 Sears Tower 233 South Wacker Drive Chicago, Illinois 60606 Mr. George' Wu11er Licensing Coordinator

~ Illinois Power Company 500 South 27th Street Decatur, Illinois 62525 5

d i

5

,7

CLINTON POWER STATION, UNIT NO. 1 CASELOAD FORECAST PANEL SITE VISIT PR_0 POSED AGENDA 1.

Overview of project construction schedule including progress and major mile-stones completed since December 1979, current problems, and any anticipated problem areas that may impact the fuel load date schedule.

Detailed review and current status of design and engineering effort including any potential problems that may arise from necessary rework.

3.

Detailed review and current status of procurement activities including valves, pipe, instruments, cable, major components, etc.

4.

Actual and proposed craft work force (by major craft), craft availability, productivity, potential labor negotiations and problems.

5.

Detailed review and current status of all large and small bore pipe hangers, restraints, snubbers, etc., including design, rework, procurement, fabrica-tion, delivery and installation.

6.

Detailed review of project schedule identifying critical path items, near critical items, amount of float for various activities, the current critical path to fuel loading and methods for implementation of corrective action for activities with negative float if any.

Estimate percent complete for Unit 1 and needed common facility as of May 31, 1980.

7.

Detailed review and current status of bulk quantities including current total estimated quantities, quantities installed to date, quantities scheduled to date, current percent complete for each, actual vs.

forecast installation rates, and basis and documentation for these figures.

(a) Concrete (CY)

(b) Process Pipe (LF)

- Large Bere Pipe (2 1/2" and larger)

- Small Bore Pipe (2" and smaller)

(c) Yard Pipe (LF)

(d) -Large Bore Pipe Hangers, Restraints, snubbers, etc. (ea)

(e) Small Bore Pipe Hangers, Restraints, etc. (ea)

(f) Cable Tray (LF)

(g) Total conduit (LF)

(h) Total exposed metal conduit (LF)

(i) Cable (LF)

- Power

- Control

- Instrumentation

- Plant Lighting

- Security

. (j) Terminations (ea)

- Power

- Control

- Instrumentation

- Plant Lighting

- Security (k) Circuits (ea)

(1)

Instrumentation (ea).

8.

Detailed review and current status of preop test procedure writing, integra-tion of. preop test activities with construction schedule, systems turnover schedule, preop test schedule, current and proposed preop test program man-power.

(a) Total number of procedures required for fuel load (b) Number of draft procedures not started Number of draft procedures being written Number of procedures approved Nember of procedures in review (f) Total number of preop test required for fuel load (g) Number of preop test completed (h) Number of preop test currently in progress.

9.

Detailed discussion of potential schedular influence due to changes attributed to.NUREG-0660 (NRC Action Plan Developed as a Result of the TMI-2 Accident) and other recent licensing requirements.

~ 10.

Detailed discussion of potential schedular impact due to the use of an incorrect soil characteristic value as design input to a computer model for developing building responses spectra which may attribute to additional work and rework.

11.

Current status and discussion of design assessment for hydrodynamic loads.

12.

Comments on the notification of a potential construction deficiency of defective plug welding on the swing dividers on some CPS control room ter-mination cabinets regarding the impact it may have on the construction schedule if any.

13. Site tour and observation of construction activities 14.

Comments on the notification of a potential construction deficiency of CRD penetration welds at and outer drywell plates regarding the impact it may have on the construction schedule if any.

15. Applicant coments of financial comitments to complete facility.