Forwards Response to IE Bulletin 80-03.Filter Housings & Replacement Cells Were Inspected.No Deficiencies Reported
ML19309G610
Person / Time
Site: Calvert Cliffs  
Issue date: 03/17/1980
From: Lundvall A
BALTIMORE GAS & ELECTRIC CO.
To: Grier B
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
IEB-80-03, IEB-80-3, NUDOCS 8005070221
Download: ML19309G610 (6)


Text

-

  • o l*

8005070221

~

R l

B ALTIMORE G AS AND ELECTRIC COMPANY P.O. B O X 147 5 B ALTIMOR E. M A RYL AN D 21203 AnTHun E. LUN OVALL,JR.

vics Paesiosar 1

Sume

]

March 17,1980 U.S. !!uclear Regulatory Commission Docket Nos.

50-317 Division of Inspection & Enforcement 50-318 Region I License Nos.

DPR-53 631 Park Avenue DPR-69 King of Prussia, PA 19406 Attention: Mr. Boyce H. Grier, Director Gentlemen:

IE Bulletin No. 80-03 concerns loss of charcoal from standard type II, 2 inch, tray adsorber cells.

Enclosures (1) and (2) to this letter respond to the items addressed in this Bulletin pertaining to Calvert Cliffs Units 1 & 2.

Should you have any questions regarding this reply, we will be pleased to discuss them with you.

~

Very truly your,

,/ -,w&u.sts-A. E. Lundvall, Jr.

Vice President-Supply AEL/ GAS /gla Enclosures cc:

J. A. Biddison, Esquire G. F. Trowbridge, Esquire E. L. Conner, Jr., NRC Office of Inspection and Enforcement, NRC R. Sanacore, American Nuclear Insurers

ENCLOSURE (1)

TYPES OF CELLS American Air Filter, Type II adsorber cells were initially installed into the Calvert Cliffs Nuclear Power Plant in 1974 and 1975 by American Air Filter representatives. All installed adsorber cells are built as pictured in Enclosure (2).

The perforated screen is rolled up around the edges and is spot welded around the perimeter of the casing with a spacing of approx-imately one (1) inch between welds.

The screen is under the frame which allows no chance of charcoal being lost during shipping, handling, storage or while in service.

The casing is of all welded construction with the exception of two (2) fill holes in the rear of the cell. These fill holes are approximately two (2) inches in diameter with covers secured with pop rivets.

In October,1979, while perfoming under FCR 78-127, the installa-tion of Nuclear Consulting test cells, various American Air Filter cells were removed and the fill covers were taken off.

All charcoal in these cells was found to be fully packed with no evidence of sagging, separation or leakage.

American Air Filter, Type II, cells are installed in the following systems:

Number of Cells Post Loci 12 Spent Fuel Pool 96 Penetration Room 12 ECCS Pump Room 24 Containment Iodine 360 504 Calvert Cliffs Nuclear Power Plant personnel have been perfoming visual inspection on all filter housings while perfoming Surveillance Test Procedures as required by Technical Specifications 3/4.6.3,3/4.6.6, 3/4.7.6, 3/4.7.7, and 3/4.9.12 in accordance with ANSI Standard N510-1973, Section 5.

These inspections by our personnel have been perfomed since 1975.

All filter housings were visually inspected on February 26, 1980, with the exception of the Containment Iodine units. These units were tested and inspected during the last refueling outages, Unit 1 on July 18, 1979, and Unit 2 on November 7,1979.

ENCLOSURE (1)

TYPES OF CELLS (CONTINUED)

All replacement cells on hand are Type II, designed and built by Nuclear Consulting and are stored properly in accordance with the American Association for Contamination Control's designation CS-8T.

Due to the construction methods utilized by Nuclear Consulting, shown in Enclosure (2), we believe that their cells will perform as well as the American Air Filter cells. A visual inspection of these replace-ment cells confirms that no leakage exists and that all screens show no evidence of sagging, i

l N

Page 1 of 3 3

N EMPTY NUCLEAR CONSULTING ADSORRFR CFII S FM

@9 M

O (M

G3 C3 ra,

_ _..' L:;f _:- _ -...,:

w...:..- :...:

.._~.__.__-=s=..

z.

_.n 1

-s

..-_-. 2.

u. 4

,6

. ~.

,s y,-

p. -- :.1u.,m-.=._,,,, _... __ _.., _ __

f y, (, '

f

-]

\\g

. a,.c..,..n. s.a...

-).

o:.,'

i

/

. w,.

,.s 4

W.;,.'

gek

..r.....-

-wn....--a4',W

's

. -(L '

r W

4

  • 3 q '5,-

n$r- --. ~..

  • q r

i

+.

?

I

.... :..... n t. x y l,,

,.1.,,.,,.

.,]s

---_. ~.

J12 2

-.._...4

., a -,, - -.. -

4

.a

_r n*

i{s.

,,'fy i '

r. -

e e

1e

  • f

} -

3) -

.?

lt t

r

.b i(

' /

4

_ '$ ' t

  • f i
  • +--e..,

s Gee i.i. :.c.t,-;_ '. '

c. _,

g 9

t

d Page 2 of 3 NUCLEAR CONSULTING ADSORBER CELL as manufactured on August 22, 1979 f W,-

r-,

b r

MES A

Screen - spot welded to the y

^

s,g -[ fe's cell housing p,9

.3' f5L }

.P Spot Welds - the spacing M.?

between welds is a

.g 8'I'

~

maximum of one(l) inch

.~

'.'.2s

-~

s s Q -; '

s

~.

" f' *-

~

s' %

s t.

x

~

~

5

'h' j!

g

.j- '.'

=

./,. '

~

..'c

'./

,~

N 3 o ~

a., = -

./,'. :. ; ;

/

, ; f * ' '.*,.,' S ';.' '3, /.. s '.;,'.'l.

  • d n

,ge, ' ;; s'

.t., e

  • N

....t,,..,..*.,'.,f,. *i. '

,..? e

  • 7, ;*..=
  • s,s

~

Ng

\\x 7

.., } N + 70' i

~

N

\\

' Y'

, ; A

?

Y'N.f.

fl

~

.J

.. '.. f.*

'.... s j

Ce11 Housing

p... ' *'. '.,- y N ' ~.,.-

.,4.'....

,e.

s

+

N

..r'.r,,,. - +,.4 *, *, +, -

y j, $,.J-

,/ <-

N, c.

,e g

.<,,'/. - -

'N *%

e, *= )

,i' /

~ 9,:

NN e, Jh.

c

\\

,I

,[b

\\ \\ g [f.bN g-

s j,*,,. ? y.'

4 Solid metal Rear Cover Plate g

'N.

pop riveted into place N.J '

Maximum Rivet Spacing is:

'N' Two(2) inches on short s' ides

)

N's /

One and one half (ll) inches s

f on long sides

T@

Q-Page 3 of 3 b

NUCLEAR CONSUM' mig TEST CEl'L '

gg

..- p

_ / 4 :% w.

r-- m

. '7 N'

Note:

This test cell is constructed in the same

..'J ' -

c==:2 g@ -

C'{' ;;, ',,,-

manner as the Nuclear Consulting adsorber Ns cell (Enclosure 2, page 2 o fj) with the s.

p '~

following exceptions:

1) The rear divider plate is welded into place A

j N

The rear test cell cover plates are

%, pop riveted into place o (,.

g..

  • %g

'; % v w

/' /

  • s;b a

., /. p.,'.c,. ' -

s tr,, *o A r.p

.'f;-e 8

3

.,, a..

/ f d', j ! ",',* ,

a ;.

.y s ';.

/=', s-j

  • ]

' E d

A

,o s

. N. s.

,/,.<<:. <.,

,y.., %..../ /

N y,

'k' *.-)"

k',*, ',,

'\\

[ ',

/

N\\

,a,,

,,-',6,',**.

, ~l,

/

p

.,., a g* e,, ?~, __' ~.

Jo,

~~

4,.. ; ',.',. a s '.:. *,,

.v

t. 4. :,.',,'/v

'~

N N.

/

4, 4

/

s

- NN

'd, 1n,,

.a

.'..a,, *,s =a,a w,. < e, ; *,/y '*/

/

j, f

s 4

s

, o

~

s

.'s,'. - o,'*-

,o-*.,/,,<,e,>.;'.'.

)?

*,,,s

,.N n

,/

s

,s

.- ~/

N,-

  • a%

/. /

I t 4 a

' I"('.

ts, f.== r p, 9 y,.. ' - *

,/

a

.N, ' x II *,'.~*,,,

s'N y

[

l ; L *,. <. a, i Rear Test Cell 4

n

+.,* *
  • v <j. [

]

Cover Plate 4

, y: s:;y 3,

f, V

x 's

'N, ;.I ' ~,(.-

/

/*

Rear Divider xN Nb'./

,/

8

(,/,

{/

o

~

'~ s.

o,s'

-. /

y

.