ML19309F499

From kanterella
Jump to navigation Jump to search
Forwards LER 80-029/03L-0
Date released: 11/19/2019 Download: ML19309F499


LER 80-029/03L-0:on 800325,condensate Storage Tank Level Switch 23-LS-74A Set Outside Tech Specs Limit.Event Recurred One Wk Later.Caused by Dirt in Switch.Switch Cleaned & Lubricated
ML19309F505
Person / Time
Site: FitzPatrick 
Issue date: 04/24/1980
From: W. Verne Childs
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19309F505 (2)
Forwards LER 80-029/03L-0
ML19309F497
Person / Time
Site: FitzPatrick 
Issue date: 04/24/1980
From: Pasternak R
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19309F497 (1)