_ _ _ - _ _ - _ _ _ _ _ _ _ _ - _ _ _ _ _ - -
'~b
{\\
i Form NRC 618 U.S. NUCLEAR REGUL ATORY COMMISSION CERTIFICATE OF COMPLIANCE 10 CFR 71 For Radioactive Materials Packages 1.(a) Certificate Number 1.(b) Revision No.
1.(c) Package Identification No.
1.(d) Pages No. 1.fel Total No Pages 9142 0
USA /9142/B( )
1
- 2. PRE AMBLE 2.fa)
This certificate is issued to satisfy Sections 173.393a 173.394,173.395, and 1733,96 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.
2.lb)
The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10 Code of Federal Regulations, Part 71," Packaging of Radmactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions."
2.(c)
This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.
- 3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.(a)
P,epared by (Name and address):
3.(b)
Title and identification of report or application:
Monsanto Research Corporation Monsanto Research Corporation application P. O. Box 8. Station B dated March 5, 1980.
Dayton, OH 45407 3.fc)
Docket No.
- 4. CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable, and the conditions specified in item 5 below.
- 5. Description of Packaging and Authorized Contents, Model Number, Fissile Class, other Conditions, and
References:
(a) Packaging (1) Model No: MRC-20WC (2) Description Packaging as described and constructed in accordance with D0T requirements of 49CFR5173.394(b)(5).
(b) Contents (1) Type and form of material Plutonium-238 sources in excess of twenty (20) curies per package shall be at least double encapsulated in a metal capsule such that the sources meet special form criteria defined in 10CFR571.4(o).
Inner and outer capsules are individually leak tested during fabrication per ANSI N542-1977, procedure A2.2.3 (He pressure bubble test), or equivalent.
8 004210 Oal
Page 2 - Certificate No. 9142 - Revision No. 0 - Docket No. 71-9142 (2) Maximum quantity of material per package.
Six (6) grams of Pu-238 (100 Ci).
6.
Sources shall be packaged to minimize possibility of secondary impacts due to normal and accident conditions of transport.
7.
The package authorized by this certificate is hereby approved for use under the general license provisions of 10CFR571.12(b).
8.
Expiration date: April 30,1982.
REFFRENCE Monsanto Research Corporation application dated March 5,1980.
FOR THE U.S. NUCLEAR REGULATORY COMMISSION
'M t
f
[3 - Charles E. MacDonald, Chief fj Transportation Certification Branch Division of Fuel Cycle and Material Safety APR 0 31980 Date:
4 e