PROPOSED REVISION 3 O
Form PJflC GIS U.S. t10CLE AR HECUL ATORY COMulSSICri 10 CF n 71 CERTIFICATE OF COMPLI AfJCE For Hadioactive Materials l'ackages e
I fel Certefeme Number 1.(bl Hevision flo.
- 1. lc) Pach ate idenreiscation PJ).
1.(d) Pages No 1.tel Fotal No. Pages 9019 3
USA /9019/B( )F 1
3
- 2. PnE AMBLE 2.(a)
This certifisate is issuet to satisf y Sections 173 393a.173.394,173,335. araf 173 3'JG of the Dep3rtment of Transpostasion Hansed Materials Hegulations 143 CFH 170180 and 14 CFR 403) and Sections 146-19-10a and 14S-19-100 of the Department of Transporlation Dangesous Caegoes Hegulasions (4G CFH 14G-149) as amended.
2 tbl The packaging and contents described in itern 5 below, meets the safely staarfarris set forth in sut;part C of Title 10. Code of Federal Regulatiuns. Part 71. ** Packaging of Fladioactive Materials for Tranwort and Transportation of Radeoactive Material Undse Ceeta.n Condia.ons."
7.lcl This certefecate does not relieve the consignoe from compliance with any reavirement of the regulations of the U.S. Department of Iransportatiors or other applicable re Julsiory agencies, enstudn.g-the government cel any countr,y through or into vehich will be transported.
3 This certific.ere is issued on the bases of a safety analyses seport of the packsge design or application-3 (s)
Prepared ley (llame and address):
3.lb)
Title and identelecation of report or application:
General Electric Company General Electric Company application dated P.O. Box 780 tiay 24,1974.
Wilmington, tic 28401 3.tc) oockei ?Jo. 71-9019 4 CONDITIONS T1.is c.etiferate is corwistional upon the fulfilling of the reavirements of Subpart D of 10 CFR 71, as applicable, and the conditeons specified in stem $ below S
Desereption of Pachaq.ng arwf Authortied Contents. Model Number. Fossile Class. Other Conditions. and Heterences.
(a)
Packaging (1) 14odel fio.: BU-7 (2) Description The packaging consists of either two, 5-gallon or three, 2.5-gallon, ll.25-inch ID, minimum 24-gauge steel pails contained in a 13.75-inch diameter by 27-inch long inner container (Uniform Freight Classification :
- Rule 40, or equivalent) constructed of minimum 18-gauge steel, with bolted and gasketed top flange closure. Tha inner container is centered and supported in a 22.5-inch ID,18-cauge steel 55-gallon capacity (Uniform Freight Classification - Rule 40, or equivalent) drum by solid insulating material composed of fire-retardant phenolic foam. The maximum weight of the package is 350 pounds.
(3) Drawing The container is constructed in accordance with Fig.1.8.1, Appendix D, of General Electric Company's application dated liay 24, 1974.
(b)
Contents (1) Type and form of material (i) Uranium oxide powder which may contain anmonium oxalate and/or l
ammonium bicarbonate as additives. Uranium may be enriched to i
l D *
- lD *D
~ 3
' T Id l
_n s K KL 80041 son g t
n:
mn aw-
PROPOSED REVISI0tl 3 Page 2 - Certificate flo. 9019 - Revision tio. 3 - Docket flo. 71-9019 (b) Contents (continued) not more than 4.0 w/o in the U-235 isotope. The maximum ll/U atomic ratio considering all sources of hydrogeneous material mixed in with the UO2 powder must be no greater than 0.45.
(ii) Uranium oxide as pellets with a maximum bulk density of 10.96 grams /cc. Uranium may be enriched to a maximum 4.0 w/o in the U-235 isotope.
(2) flaximum quantity of material per package (i) For the contents described in 5(b)(1)(i):
The maximum contents per package and pail for the maximum U-235 enrichment shall be limited in accordance with the following table:
Maximum U-235 Maximum 00 tiaximum U02 enrichnent, per pail, 2 per package, w/o kgs kgs 3.0 44.5 89.0 3.2 38.9 77.8 3.4 34.6 69.2 3.6 31.1 62.2 3.8
-28.3 56.6 4.0 25.7 51.4 (ii) For the contents described in 5(b)(1)(ii):
The maximum contents per package and pail for the maximum U-235 enrichment shall be limited in accordance with the following table:
flaximum U-235 Maximum 00 Maximum U02 enrichment, per pail, 2 per package, w/o kgs
- kgs 2.7 45.0 90.0 2.8 42.9 85.8 2.9 40.1 80.2 3.0 38.1 76.2 3.2 34.1 68.2 3.4 31.0 62.0 3.6 28.5 57.0 3.8 26.4 52.0 4.0 24.7 49.4
= 1: h.%'"m'.'r d' Tx"&&&f 'W F'h*?~f."T:.~ ":?h:sEh???w+M =~ ~'
2-
PROPOSED REVISION 3 Page 3 - Certificate flo. 9019 - Revision flo. 3 - Docket lio. 71-9019 (c) Fissile Class 6.
For mixtures of contents (powders and pellets) described in 5(b)(1), the maximum quantity of material per package shall be limited to the quantity given in 5(b)(2)(ii).
7.
For mixtures of contents as described in 5(b)(1)(i), amonium oxalate (AO) and/or ammonium bicarbonate (ABC) additives are permitted in the UO2 powder provided that their presence is taken into account in the determination of the H/U ratio in the package as follows:
flH (water) + flg (additive) + 0.038 flC (additive) ilU (UO2 powder) s 0.45 Where flg (water)
= atom density of hydrogen in the UO2 powder mixture in the fom of water flH (additive) = atom density of hydrogen in the U02 powder mixture in the form of A0 and/or ABC flC (additive) = atom density of carbon in the U02 powder mixture in the form of A0 and/or ABC NU
= atom density of uranium in the UO2 powder mixture 8.
The density of the package insulation shall not be less than 8 lbs/cu ft for the side and bottom and 20 lbs/cu ft for the top.
9.
The four,1/4-inch diameter holes located near the top of the outer 55-gallon Rule 40 drum as shown in Fig.1.8.1 shall be covered with weatherproof tape to preclude the entry of water.
10.
The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).
11.
Expiration date:
REFEREilCE General Electric Company application dated May 24, 1974.
. _. =: ?==u c::rmw--mmmm ww.mw.-num n~
G E N E R A L [8 E LE CTRIC arch 14 9b ATTACHMENT 5 APPLICATION FOR BU-7 LICENSE DATED MAY 4, 1974 i
A.
L.
Kaplan
- bmw t
.--o, e m -
- - - - -