ML19309E103

From kanterella
Jump to navigation Jump to search
Forwards Revision to Section 5.4 of Fundamental Nuclear Matl Control Plan
ML19309E103
Person / Time
Site: Wood River Junction
Issue date: 01/17/1980
From: Gregg R
UNC RECOVERY SYSTEMS, UNITED NUCLEAR CORP. (SUBS. OF UNC, INC.)
To: Partlow J
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
References
15241, NUDOCS 8004180392
Download: ML19309E103 (2)


Text

fil

=

Qg 70- rzo

.s

~

UnC RECOVERY SYSTEMS 7

Divisicq cf United Nuclear Corporat on One Na'ragr : ' Tra,I Tc'er, hone 401/ 364-7701 g

A UnC RESOURCES Company Wood Riva* u. t on Rhode Island 0289.:

fnupN

/Q'llECE jygg e

OAll2 C

s.:.

2 '9SO a

',lil January 17, 1980 3,,"

,/

MQA:

80-08 4.

4 f/

IU United States Nuclear Regulatory Commission James G.

Partlow, Chief Material Control Licensing Branch Divisicn of Safeguards Washirigton, D.C.

20555 i

i

Reference:

Letter, James G.

Partlow to C.

E. Bowers dated July 6, 1979 Gentlemen:

Attached you will find a revision to Section 5.4 of the UNC RS Fundamental Nuclear Material Control Plan (FNMC).

This change is submitted in response to the referenced letter and in accordance with 10CFR 70.32 (c).

If you desire any further information regarding this submittal, please contact us.

Very truly yours, 1

(

R.

J. Greg Manager Quality Assurance RJG: maw Attachment cc:

C. E.

Bowers J. H. L'Heureux 15241 80041so $ A

  • WP, 505-2
  • t Chango 4 5.4 Schedules for Inventories Physical inventories of high-enriched uranium shall be per-formed at intervals not exceeding 65 days, with a minimum of six inventories per calendar year.

Inventories of low-enriched uranium will be performed at intervals not to exceed 210 days with a minimum of two inventories per calendar year.

5.5 Preparations for Inventories Special procedures for conducting the Physical Inventory are as follows:

5.5.1 Sealed Containers j

All sealed materials will be entered in the Inven-tory Control Roster.

The roster shall include con-tainer number, job number, description, location, grams uranium, grams U-235, and assay method.

In-process materials will be reduced to.a minimum con-sistent with plant operation at cutoff time.

Once listed, a container is frozen until released by the Manager, QA.

5.5.2 Conversion of SNM Efforts will be made to' convert as much in-process material as possible to ADU or uranium oxide, which can be readily sampled, weighed, and assayed.

All material will be measured by weight or volume, after a thorough mixing in its container, and assayed.

5.5.3 Process Containers All containers used for storage or processing will either be entered into the Inventory' Control Roster i

or emptied and cleaned prior to the cutoff date.

Equipment and containers are inspected to insure that the listing is complete, seals have not been compro-mised, and that each has been entered in the Inven-tory Control Roster.

The roster is then reconciled with the MBA and ICA records and forwarded to QA for completion of inventory calculations under the supervision of the Manager, QA.

Seal and item iden-tifications will be listed in coded form as deemed convenient on all inventory records.

5.5.4 Inventory Teams Qualified personnel (a minimum of two individuals working in conjunction with each other) shall be assigned to each inventory team.

16241

.