e "'4g a
p UNITED STATES g
q.
g NUCLEAR REGULATORY COMMISSION 18 REGION il
+9 *...,o#[
101 MARIETTA ST N.W.. SUITE 3130 ATLANTA, G EORGI A 30303 x_;
FEB 2 C 1980 In Reply Refer To:
Ril:GLT 70-1151/80-3 Westinghouse Electric Corporation ATTN:
M. D'Amore, Manager Columbia Plant Nuclear Fuel Division Drawer R Columbia, SC 29205 Gentlemen:
This refers to the inspection conducted by G. L. Troup of this office on February 4-8, 1980, of activities authorized by NRC License No. SNM-1107 for the Columbia Fuel Fabrication facility, and to the discussion of our findings held with M. D'Amore at the conclusion of the inspection.
Areas examined during the inspection and our findings are discussed in the enclosed inspection report. Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations by the inspector.
Within the scope of this inspection, no items of noncompliance were disclosed.
We have examined actions you have taken with regard to previously identified enforcement matters. These are discussed in the enclosed inspection report.
In accordance with Section 2.790 of the NRC's " Rules of Practice", Part 2, Title 10, Code of Federal Regulations, a copy of this lettet and the enclosed inspection report will be placed in the NRC's Public Document Room.
If this report contains any information that you (or your contractor) believe to be proprietary, it is necessary that you make a written application within 20 days to this of fice to withhold such information from public disclosure. Any such application must include a full statement of the reasons on the basis of which it is claimed that the information is proprietary, and should be prepared so that proprietary information identified in the application is contained in a separate part of the document.
If we do not hear from you in this regard within the specified period, the report will be placed in the Public Document Room.
8 0 0411 oeOl4 l
E 6198f l
I f.,.
Westinghouse Electric Corporation -
4
'Should you have any questions concerning this letter, we will be glad to discuss i
them with you.
l Sincerely, J
r c
M
. Philip St r,
hief r
i Fuel Facility and Materials Safety Branch i
Enclosure:
Inspection Report No. 70-1151/80-3 i
I i
1 I
- .\\
. -.