ES-401 Generic Knowledge and Abilities Outline (Tier 3)

Form ES-401-3 Facility: Clinton Nuclear Power Station Date of Exam: September 9 - 20, 2019 Category K/A #

Topic RO SRO-only IR IR

1. Conduct of Operations 2.1.28 G2.1.28 - Knowledge of the purpose and function of major system components and controls.

(CFR: 41.7) 4.1 66 2.1.31 G2.1.31 - Ability to locate control room switches, controls, and indications, and to determine that they correctly reflect the desired plant lineup.

(CFR: 41.10 / 45.12) 4.6 67 2.1.25 G2.1.25 - Ability to interpret reference materials, such as graphs, curves, tables, etc.

(CFR: 41.10 / 43.5 / 45.12) 3.9 68 2.1.6 G2.1.6 - Ability to manage the control room crew during plant transients.

(CFR: 41.10 / 43.5 / 45.12 / 45.13) 4.8 94 2.1.36 G2.1.36 - Knowledge of procedures and limitations involved in core alterations.

(CFR: 41.10 / 43.6 / 45.7) 4.1 95 Subtotal 3

2

2. Equipment Control 2.2.14 G2.2.14 - Knowledge of the process for controlling equipment configuration or status.

(CFR: 41.10 / 43.3 / 45.13) 3.9 69 2.2.39 G2.2.39 - Knowledge of less than or equal to one hour Technical Specification action statements for systems.

(CFR: 41.7 / 41.10 / 43.2 / 45.13) 3.9 70 2.2.5 G2.2.5 - Knowledge of the process for making design or operating changes to the facility.

(CFR: 41.10 / 43.3 / 45.13) 3.2 96 2.2.44 G2.2.44 - Ability to interpret control room indications to verify the status and operation of a system, and understand how operator actions and directives affect plant and system conditions.

(CFR: 41.5 / 43.5 / 45.12) 4.4 97 Subtotal 2

2

3. Radiation Control 2.3.7 G.2.3.7 - Ability to comply with radiation work permit requirements during normal or abnormal conditions.

(CFR: 41.12 / 45.10) 3.5 71 2.3.12 G2.3.12 - Knowledge of radiological safety principles pertaining to licensed operator duties, such as containment entry requirements, fuel handling responsibilities, access to locked high-radiation areas, aligning filters, etc.

(CFR: 41.12 / 45.9 / 45.10) 3.2 72 2.3.14 G2.3.14 - Knowledge of radiation or contamination hazards that may arise during normal, abnormal, or emergency conditions or activities.

(CFR: 41.12 / 43.4 / 45.10) 3.8 98 Subtotal 2

1

4. Emergency Procedures/Plan 2.4.4 G2.4.4 - Ability to recognize abnormal indications for system operating parameters that are entry-level conditions for emergency and abnormal operating procedures.

(CFR: 41.10 / 43.2 / 45.6) 4.5 73 2.4.14 G2.4.14 - Knowledge of general guidelines for EOP usage.

(CFR: 41.10 / 45.13) 3.8 74 2.4.39 G2.4.39 - Knowledge of RO responsibilities in emergency plan implementation.

(CFR: 41.10 / 45.11) 3.9 75

ES-401 Generic Knowledge and Abilities Outline (Tier 3)

Form ES-401-3 2.4.30 G2.4.30 - Knowledge of events related to system operation/status that must be reported to internal organizations or external agencies, such as the State, the NRC, or the transmission system operator.

(CFR: 41.10 / 43.5 / 45.11) 4.1 99 2.4.44 G2.4.44 - Knowledge of emergency plan protective action recommendations.

(CFR: 41.10 / 41.12 / 43.5 / 45.11) 4.4 100 Subtotal 3

2 Tier 3 Point Total 10 7