f/0 TENNEOSEE VALLEY AUTHORITY
[NI JWo CH ATTANOOGA, TENNESSEE 37401 400 Chestnut Street Tower II March 21, 1980
.-i r
- a Mr. James P. O'Reilly, Director
?)
Office of Inspection and Enforcement
- e..
U.S. Nuclear Regulatory Commission Region II - Suite 3100 m
101 Marietta Street er Atlanta, Georgia 30303
Dear Mr. O'Reilly:
~
~
OFFICE OF INSPECTION AND ENFORCEMENT (IE) BULLETIN 79-23, DATED SEPTEMBER 12, 1979, J. P. O'REILLY TO H. G. PARRIS In response to IE Bulletin 79-23 we have conducted a sustained full-load operational test on emergency diesel generator 3A at the Browns Ferry Nuclear Plant. The test was completed on January 6, 1980.
This test, with a typical diesel generator, demonstrated the ability of the diesel generators to function properly over a 24-hour period at the specified loads.
The successful completion of this testing completes the action required by IE Bulletin 79-23 for Browns Ferry. If you have any questions, please call Jim Domer at FTS 854-2014.
Very truly yours, TENNESSEE VALLEY AUTHORITY L. M. Mills, Mana er Nuclear Regulatf M and Safety
~
i 4.M-An Equal Opportunity Employer l
8004100364 o
3