ML19309D286
| ML19309D286 | |
| Person / Time | |
|---|---|
| Site: | 07106272 |
| Issue date: | 03/28/1980 |
| From: | Macdonald C NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| To: | |
| Shared Package | |
| ML19309D282 | List: |
| References | |
| NUDOCS 8004100216 | |
| Download: ML19309D286 (2) | |
Text
--- - -
form NAC C'8 U.S. NUCLE AR REGULATORY COMMISSION H2 73)
CERTIFICATE OF COMPLIANCE
,g gp g,,
For Radioactive Materials Packages 1.(a) Certi icate Number 1.(b) Revision No.
1.(c) Package identification No.
IJd) PagesNoj 1 (e) Total No. Pages f
6272 3
USA /6272/Bf 1 1 1 2
- 2. PRE AMBLE 2.fal This certificate is issued to satisfy Sections 173.393a.173.394.173.395, and 173.396 of the Department of Transportation Harardous Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-104 and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulatioris (46 CFR 146-149), as amended.
2.lb)
The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10. Code of Federal Regulations. Part 71, ** Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions.
2.fc)
This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.
- 3. This certificate is issued on the basis of a safety analysis report of the package design or apodication-3.(a)
Prepared by (Name and address):
3.lb)
Title and identification of report or application:
Nuclear Engineering Company, Inc.
Protective Packaging, Inc. application P.O. Box 7246 dated June 24, 1974, as supplemented Louisville, KY 40207 3.(C)
Docket No.
71 6272 4 CON 0lTIONS This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicable, and the conditions specified in item S below.
- 5. Description of Packaqsng and Authorized Contents, Model Number, Fissile Class, Other Conditions, and References.
(a) Packaging:
(1) Model No.: 6272 (2) Description A protective overpack having a double-walled, low-carbon steel shell (3/16" outer wall and 20 guage inside wall) with rigid polyurethane foam (nominally 7" thick) thermal-snock insulation between the walls. The edges of the overpack are reinforced with 10 guage steel angles welded to the outer face of the walls and internal diagonal 14 guage steel plates. Overpack lid closure is provided by three, 1" steel rods which extend the full width, welded to an end plate at one end and secured by a pin at the other end.
Enclosed within the overpack is a bolted and gasketed,12 guage low carbon steel inner container. The gross weight of the package is about 6,100 pounds.
(3) Drawings The overpack is constructed in accordance with Mechanics Research, Inc.,
Drawing No. 121347, revised to May 21, 1970. The waste storage bin (inner container) is constructed in accordance with Argonne National Laboratory's Drawing No. CS-2273.
Ndb
a Page 2 - Certificate flo. 6272 - Revision No. 3 - Docket No. 71-6272 h
5.
(b) Contents (1) Type and form of material Dry, solid radioactive material within the waste storage bin.
I (2) Maximum quantity of material per package Not to exceed Type B quantities of radioactivity. The.mximum weight of the contents shall not exceed 3,000 pounds.
6.
Contents within the inner container must be either packed full or must be securely braced to prevent movement.
7.
The cover of the inner container must be secured by at least 20 bolts (5 per side) of not less than 5/16-inch diameter.
8.
Prior to each shipment the inner container lid gasket shall be inspected.
The gasket shall be replaced if inspection shows any defects or every twelve (12) months, whichever occurs first.
9.
The package authorized by this cerificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).
10.
Expiration date: March 31, 1985.
l REFERENCES Protective Packaging, Inc. application dated June 24, 1974.
Supplement dated: January 28, 1975.
FOR THE U.S. NUCLEAR REGULATORY COMMISSION Y
Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety Date:
MAR 2 81980 W
K;.
m, lid