J Form NRC 618 U.S. NUCLE AR REGUL ATORY COMMISSION II CERTIFICATE OF COMPLIANCE g CFR 71 For Radeoactive Materials Packages 1.f a) Certificate Number 1.(b) Revision No.

1.(c) Package identification No.

1.(d) Pages No. 1 (e) Total No. Pages 6679 3

USA /6679/Bf 1F l

4

2. PRE AMBLE 7.(a)

This cetteficate is issued to satisf y Sections 173.393a.173.394,173.395, and 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170189 and 14 CFR 103) and Sections 146-19-10a and 14G-19-100 of the Department of Transportation Dangerous Cargoes Regulations (4G CF R 146-149L as amended.

2.(b)

The paciraging and contents described en item 5 below, meets the safety standards set forth in Subpart C of Title 10. Code of Federal Regulations Part 71, " Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions!

2.(c)

This certificate does not reheve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or into which the package will be transported.

3. This certificate is issued on the basis of a safety analysis report of the package design or application-3 (a)

Prepared by (Name and address):

3.(b)

Title and identification of report or application:

auclear Engineering Company, Inc.

Protective Packaging, Inc. application P.O. Box 7246 dated September 26, 1974 Louisville, KY 40207 3.(c)

Dock et No.

7].6679 4.

CONDillONS This certificate is entwbtional upon the fulfilling of the requirements of Subpart D of 10 CF R 71, as apphcable, and the conditions specified in item 5 helnw.

5. Description of Packaging arw1 Authorized Contents, Model Number, Fissile Class, Other Conditions, and

References:

(a)

Packaging (1) Model No.:

6679 l

(2) Description A protective overpack which provides containment, impact resistance and thermal resistance for its contents.

The containment vessel (cavity) is approximately 76" x 76" x 85" constructed of 3/16" thick and 10-gage mild steel. Closure of the containment vessel is by 1/4" thick aluminum plate with silicone rubber gasket which is bolted to the containment vessel. A pressure fitting with cap on the closure plate provides a means for leak testing. The containment vessel is centered and supported in an outer 3/16" thick steel jacket by approximately 17" of polyurethane foam insulation at the end and 10" on the sides.

A removable section or cap consisting of approximately 18" of polyurethane foam insulation encased in steel with a silicone rubber gasket is bolted to the main outer steel jacket.

The overall dimensions of the packages are,approximately 96" x 96" x 120".

Vent holes are provided on the sides and ends of the container.

Set into each corner of the outer container are standard I.S.0. steel castings. The maximum total weight including weight of the contents is 45,000 pounds.

(3) Drawings Packaging is constructed in accordance with Protective Packaging, Inc.,

Drawing Nos. 32106-3, Sheet 1, Revision F and 32106, Sheet 2.

8004100200

I in Page 2 - Certificate No. 6679 - Revision No. 3 - Docket No. 71-6679 5.

(a) Packaging (continued)

(3) Drawings (continued)

Argonne Transportation Shield is constructed in accordance with Drawing Nos. 32269, 32268, Revision A and 322170, Revision A.

ANL Wasta storage bin is constructed in accordance with Drawing No. CS 2273.

(b) Contents (1) Type and form of material (i) Radioactive material including fissile material as solids or liquids, in normal or special form packaged in secondary packaging which meets DOT Specification 7A, Type A general packaging.

(ii) Radioactive material including fissile material as solids, in normal or special form packaged in secondary packaging which meets DOT Specification 17C or 17H 55-gallon steel drums.

Fissile material concentration shall be no more than 5 grams fissile material in any liter.

(iii) Radioactive material including fissile material as solids, in normal or special form packaged in secondary pacakaging which meets DOT Specification 7A, Type A general packaging.

(iv) Radioactive material including fissile material as dry solids in normal or special form packaged in ANL waste storage bins contained within the Argonne Transportation Shield.

(2) Maximum quantity of material per package (1) For the contents described in 5(b)(1)(i):

Greater than Type A quantity of radioactive material in secondary packaging.

Fissile material contents not to exceed the generally licensed mass limits as specified in 10 CFR 571.11.

(ii) For the contents described in 5(b)(1)(ii):

Greater than Type A quantity radioactive materials in1 secondary packaging.

Eighteen, 17C or 17H 55-gallon steel drums.

Each drum is limited to a maximum of 200 grams fissile material with no more than 5 grams fissile material in any liter and a maximum of 200 pounds of graphite.

(iii) For the contents described in 5(b)(1)(iii):

Greater than Type A quanity radioactive material in secondary packaging.

Not more than 5 grams /ft3 fissile material,

I Page 3 - Certificate No. 6679 - Revision No. 3 - Docket tio. 71-6679 5.

(b) Contents (continued)

(2) liaximum quantity of material per package (continued)

(iv)

For the contents described in 5(b)(1)(iv):

Greater than Type A quantity radicactive materials.

Fissile material contents not to exceed the generally licensed mass limits as specified in 10 CFR 571.11.

(c) Fissile Class I, II and III (1) Fissile Class I for the contents described in 5(b)(1)(ii) and 5(b)(1)(iii) and limited in 5(b)(2)(ii) and 5(b)(2)(iii).

(2) flinimum transport For the contents described in 5(b)(1)(i) index to be shown on and 5(b)(1)(iv) and limited in 5(b)(2)(i) and label for Class II 5(b)(2)(iv):

As prescribed by 10 CFR 571.ll(b).

(3) fiaximum number of For the contents described in 5(b)(1)(i) and packages per shipment 5(b)(1)(iv) and limiLted in 5(b)(2)(i) and for Class III 5(b)(2)(iv):

One (1) 6.

The maximum gross weight of the package including contents, secondary packaging, dunnage, shoring and bracing must not exceed 45,000 pounds.

7.

The maximum decay heat generation per package must not exceed:

(i) 15 watts and the heat sources are distributed throughout the cavity such that the temperature at any point within the cavity does not exceed 200 F, or (ii) 104 watts provided combustible solids or liquids are not present and the heat sources are distributed throughout the cavity such that the internal surface temperature of the cavity walls will nowhere exceed 350 F.

(iii) 157 watts provided the ANL waste storage b!ns and transportation shield are used, combustible solids or liquids are not present and the heat sources are distributed throughout the cavity such that the internal surface temperature of the cavity wall will nowhere exceed 350 F.

8.

The contents described in 5(b)(1)(ii) and limited in 5(b)(2)(ii) may be intermixed with the contents described in 5(b)(1)(iii) and limited in 5(b)(2)(iii).

9.

For less than full loads, sufficient dunnage, shoring and/or bracing shall be utilized to minimize secondary impact of the Type A packaging within the cavity under normal and accident conditions.

P-l Page 4 - Certificate No. 6679 - Revision No. 3 - Docket No. 71-6679 10.

Protrusions from Type A packaging such as lifting eyes, etc., shall be positioned such that they will not contact the cavity walls, or shoring shall be provided to prevent puncture of the cavity walls by the protrusions under the normal and accident conditions.

11. Radiation shielding as required shall be an intergral part of the Type A packaging.

12.

Contents shall be positioned in the cavity such that the center of gravity of the loaded package is substantially the same as the center of gravity of an empty package.

13. A leak test shall be conducted of each Model No. 6679 packaging prior to delivery to a carrier for transport to ensure that it is properly sealed. Where the Argonne Transportation Shield is used, the leak test may be conducted on the Argonne Trans-portation Shield in lieu of the Model No. 6679 packaging.

14.

Prior to each shipment the containment vessel silicone rubber gasket shall be inspected. The gasket shall be replaced if inspection shows any defects or every twelve (12) months, whichever occurs first.

15.

Shipment of liquids where freezing may be encountered must receive approval with regard to arrangment made to prevent freezing of the contents.

16.

The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).

17.

Expiration date:

July 31, 1980.

REFERENCE Protective Packaging, Inc. application dated September 26, 1974.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION (Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Mater'al Safety Date:

3 I 1980

.